Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study

dc.contributor.affiliationUniversidad de Las Américas
dc.contributor.authorGarrido-Osorio, Víctor
dc.contributor.authorFuentes-Barría, Héctor
dc.contributor.authorSanhueza-González, Sebastián
dc.contributor.authorSandoval-Jelves, Catarí
dc.contributor.authorAguilera-Eguía, Raúl
dc.contributor.authorRojas-Gómez, Diana
dc.contributor.authorRoco-Videla, Ángel
dc.contributor.authorCaviedes-Olmos, Marcela
dc.date.accessioned2026-08-28T20:53:22Z
dc.date.issued2025-11
dc.description.abstractBackground/Objectives: Low-cost portable load cell dynamometers allow for real-time assessment of muscular strength. This study evaluated the reliability and repeatability of the G-Force load cell system during isometric hip abduction and adduction in young physically active Chilean adults. Methods: In total, 24 participants (19 men, 5 women) performed two maximal voluntary contractions per movement, repeated after a 24 h interval. Measured variables included Peak Force, peak rate of force development (Peak RFD), RFD at 50, 100, and 200 ms (RFD50, RFD100, RFD200), and maximum jerk. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV%) and Bland–Altman plots. Results: Peak Force showed excellent within-day (ICC = 0.94–0.96) and high between-day reliability (ICC = 0.87–0.89; CV = 20–30%). Bland–Altman analysis indicated negligible bias for Peak Force in abduction (−6.54 N; 95% CI −19.55 to 6.47) and adduction (−17.57 N; 95% CI −37.24 to 2.09), confirming the absence of systematic error. Peak RFD, RFD50–200, and maximum Jerk showed moderate repeatability and lower between-day reliability (ICCs = 0.39–0.70; CVs = 34–57%), indicating higher variability in explosive force indices compared with maximal strength. Conclusions: The G-Force load cell reliably measures maximal isometric hip strength, while Peak RFD, RFD50–200, and maximum jerk should be interpreted cautiously. These findings support the device as a practical, low-cost tool for sports and rehabilitation, though future studies should validate dynamic indices in larger and more diverse populations. © 2025 by the authors.
dc.description.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.format.mimetypeapplication/pdf
dc.identifier.citationGarrido-Osorio, Víctor; Fuentes-Barría, Héctor; Sanhueza-González, Sebastián; Sandoval-Jelves, Catarí; Aguilera-Eguía, Raúl; Rojas-Gómez, Diana; Roco-Videla, Ángel; Caviedes-Olmos, Marcela (2025). Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study. Applied Sciences (Switzerland), 15(21), 11457. https://doi.org/10.3390/app152111457
dc.identifier.doihttps://doi.org/10.3390/app152111457
dc.identifier.issn20763417
dc.identifier.rorhttps://ror.org/0166e9x11
dc.identifier.scopusauthorid58511155900
dc.identifier.scopusauthorid7801441851
dc.identifier.scopusauthorid60190300700
dc.identifier.scopusauthorid60190347700
dc.identifier.scopusauthorid30867480100
dc.identifier.scopusauthorid23135717400
dc.identifier.scopusauthorid57197820869
dc.identifier.scopusauthorid58010243400
dc.identifier.urihttps://repositorio.udla.cl/handle/udla/2320
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.isindexedbyWeb of Science
dc.relation.isindexedbyScopus
dc.rightsCreative Commons Attribution 4.0 International
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceApplied Sciences (Switzerland)
dc.subjectmuscle strength
dc.subjectmuscle strength dynamometer
dc.subjectisometric contraction
dc.subjecthip joint
dc.subject.oecd13 Ciencias Médicas y de la Salud
dc.subject.oecd23.3 Ciencias de la Salud
dc.subject.oecd33.3.3 Enfermería
dc.titleReliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study
dc.typejournal article
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.driverinfo:eu-repo/semantics/article
oaire.citation.endPage11457
oaire.citation.issue21
oaire.citation.startPage11457
oaire.citation.titleApplied Sciences (Switzerland)
oaire.citation.volume15
udla.area.fuente9 Salud
udla.campusProvidencia
udla.campus.adscripcionPR
udla.carreraENFERMERÍA
udla.carrera.adscripcionENFERMERÍA
udla.curacion.estadoCURADO_COMPLETO
udla.escuelaEnfermería
udla.escuela.adscripcionEnfermería
udla.facultadFacultad de Salud y Ciencias Sociales
udla.facultad.adscripcionFacultad de Salud y Ciencias Sociales
udla.facultad.codigoFSCS
udla.oecd.area3 Ciencias Médicas y de la Salud
udla.oecd.discipline3.3.3 Enfermería
udla.oecd.subarea3.3 Ciencias de la Salud
udla.sjr.quartileQ2
udla.tipo.autorPrincipal
udla.tipo.participanteAcadémico Regular
udla.tipo.publicacionArtículo

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
174.pdf
Size:
3.32 MB
Format:
Adobe Portable Document Format

Collections