Publication:
Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators

dc.contributor.affiliationUniversidad de Las Américas
dc.contributor.authorVasquez-Bonilla, Aldo A.
dc.contributor.authorYáñez-Sepúlveda, Rodrigo
dc.contributor.authorMonsalves-Álvarez, Matías
dc.contributor.authorTuesta, Marcelo
dc.contributor.authorDuclos-Bastías, Daniel
dc.contributor.authorCortés-Roco, Guillermo
dc.contributor.authorOlivares-Arancibia, Jorge
dc.contributor.authorGuzmán-Muñoz, Eduardo
dc.contributor.authorLópez-Gil, José Francisco
dc.date.accessioned2026-08-28T20:46:16Z
dc.date.issued2025-06
dc.description.abstractObjectives: This study aimed to evaluate the reliability of muscle oxygen saturation (SmO2) and its correlation with variables from an inertial measurement unit (IMU) sensor placed on the knee at different exercise intensities. Methods: Fourteen university athletes participated in the study. Incremental ergospirometry was performed to exhaustion to calculate V’O2max, determine training zones, heart rate, and workload using the IMU, and analyze muscle metabolism by SmO2. Results: The analysis revealed significant differences between moderate-to-high-intensity zones (80–89% vs. 50–69%, Δ = 27% of SmO2; p < 0.001) and high-intensity zones (90–100% vs. 50–79%, Δ = 35% of SmO2; p < 0.001). SmO2 values showed moderate reliability at moderate exercise intensities (e.g., ICC 0.744 at 50%) and high variability at higher intensities, with ICC values around 0.577–0.594, and CV% increasing up to 77.7% at 100% intensity, indicating decreasing consistency as exercise intensity increases. SmO2 significantly decreases with increasing angular velocity (β = −13.9, p < 0.001), while knee joint load only shows significant correlations with SmO2 in the moderate-to-high-intensity zones (r = 0.569, p = 0.004) and high-intensity zones (r = 0.455, p = 0.012). Conclusions: SmO2 is a key predictor of performance during maximal incremental exercise, particularly in high-intensity zones. Moreover, SmO2 has the potential to serve as a physiological marker of the internal load on the muscles surrounding the knee during exercise. The SmO2 decrease could depend on the angular velocity and impact of the exposed knee during running. © 2025 by the authors.
dc.description.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.format.mimetypeapplication/pdf
dc.identifier.citationVasquez-Bonilla, Aldo A.; Yáñez-Sepúlveda, Rodrigo; Monsalves-Álvarez, Matías; Tuesta, Marcelo; Duclos-Bastías, Daniel; Cortés-Roco, Guillermo; Olivares-Arancibia, Jorge; Guzmán-Muñoz, Eduardo; López-Gil, José Francisco (2025). Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators. Journal of Functional Morphology and Kinesiology, 10(2), 136. https://doi.org/10.3390/jfmk10020136
dc.identifier.doihttps://doi.org/10.3390/jfmk10020136
dc.identifier.issn24115142
dc.identifier.orcidhttps://orcid.org/0000-0002-7186-3941
dc.identifier.researcheridGCJ-3825-2022
dc.identifier.rorhttps://ror.org/0166e9x11
dc.identifier.scopusauthorid57192810947
dc.identifier.scopusauthorid57191875417
dc.identifier.scopusauthorid56076647200
dc.identifier.scopusauthorid55357715300
dc.identifier.scopusauthorid57211752928
dc.identifier.scopusauthorid57925708500
dc.identifier.scopusauthorid57205271934
dc.identifier.scopusauthorid56520381200
dc.identifier.scopusauthorid57211391916
dc.identifier.urihttps://repositorio.udla.cl/handle/udla/2201
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.isindexedbyWeb of Science
dc.relation.isindexedbyScopus
dc.rightsCreative Commons Attribution 4.0 International
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceJournal of Functional Morphology and Kinesiology
dc.subjectskeletal muscle
dc.subjectknee
dc.subjectexercise
dc.subjectoxygen uptake
dc.subject.oecd13 Ciencias Médicas y de la Salud
dc.subject.oecd23.3 Ciencias de la Salud
dc.subject.oecd33.3.11 Ciencias del Deporte y Acondicionamiento Físico
dc.titleReliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators
dc.typejournal article
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.driverinfo:eu-repo/semantics/article
dspace.entity.typePublication
oaire.citation.endPage136
oaire.citation.issue2
oaire.citation.startPage136
oaire.citation.titleJournal of Functional Morphology and Kinesiology
oaire.citation.volume10
udla.area.fuente6 Educación
udla.campusProvidencia
udla.campus.adscripcionCC
udla.carreraPEDAGOGÍA EN EDUCACIÓN FÍSICA
udla.carrera.adscripcionPEDAGOGÍA EN EDUCACIÓN FÍSICA
udla.curacion.estadoCURADO_COMPLETO
udla.escuelaEducación Física
udla.escuela.adscripcionEducación Física
udla.facultadFacultad de Educación
udla.facultad.adscripcionFacultad de Educación
udla.facultad.codigoFEDU
udla.oecd.area3 Ciencias Médicas y de la Salud
udla.oecd.discipline3.3.11 Ciencias del Deporte y Acondicionamiento Físico
udla.oecd.subarea3.3 Ciencias de la Salud
udla.sjr.quartileQ1
udla.tipo.autorSecundario
udla.tipo.participanteAcadémico Regular
udla.tipo.publicacionArtículo

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
59.pdf
Size:
994.53 KB
Format:
Adobe Portable Document Format

Collections