QUIDEL CATRILELBUN, MAURICIO ELÍAS LEANDRO
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0002-6603-9093 ↗
Scopus Author ID 57207031574 ↗
ResearcherID (Web of Science) DPD-9435-2022 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
2 resultados
Publicaciones
Mostrando 1 - 2 de 2
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Delineating the Role of Inter-Repetition Interval in the Relationship between Maximum Repetitions to Failure or Repetitions in Reserve and Movement Velocity(SAGE PUBLICATIONS INC, 2025-11) ;MARTÍNEZ-RUBIO, CARLOS ;BAENA-RAYA, ANDRÉS; ;RODRÍGUEZ-PÉREZ, MANUEL A.PÉREZ-CASTILLA, ALEJANDROBackground: Maximum repetitions to failure (RTF) and repetitions in reserve (RIR) can be estimated through fastest mean velocity (MVfastest) and mean velocity (MV), respectively. However, the impact of inter-repetition intervals (IRI) on these relationships in free-weight back squat and bench press exercises is unclear. Hypothesis: The IRI would affect RTF-MVfastest and RIR-MV relationships, with a higher goodness-of-fit using self-selected IRI (SSIRI) compared with 0 seconds (IRI0) and 3 seconds (IRI3). Study Design: Crossover study design. Level of Evidence: Level 3. Methods: Eighteen male participants completed 1 session per IRI configuration, consisting of 3 single sets of RTF (65%-75%-85% of the 1-repetition maximum) during the free-weight back squat and bench press exercises. Results: Individualized RTF-MVfastest and RIR-MV relationships were stronger than generalized (median R2 = 0.98 vs 0.65 and 0.84 vs 0.40, respectively). The goodness-of-fit of the relationships was stronger for SSIRI than for IRI0 during back squat (P < .01) and comparable between IRIs during bench press (P >= .28). During back squat, MVfastest values were higher for IRI0 than for IRI3 and SSIRI (eighth-fifteenth repetitions; P <= .07), whereas during the bench press, they were higher for IRI0 than for IRI3 (eleventh-fifteenth repetitions; P >= .28). Overall, MV values associated with each RIR were higher for IRI0 than for SSIRI (10 out of 18 comparisons) during back squat, and for IRI0 than for IRI3 and SSIRI (16 and 14 out of 18 comparisons) during bench press. Conclusion: These results highlight the importance of standardizing the IRI during set-to-failure to establish RTF-MVfastest and RIR-MV relationships, with SSIRI recommended as a more accurate and effective procedure. Clinical Relevance: This information may provide practitioners with a valuable tool to objectively quantify the level of effort being exerted during resistance training sets by measuring movement velocity in free-weight exercises. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study(MDPI, 2025-11-22); ;FUENTES-BARRÍA, HÉCTOR ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 +/- 4.97 years; body mass index: 25.79 +/- 3.02 kg/m(2)) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland-Altman analysis and Pearson's correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86-0.91) and moderate-to-good inter-platform reliability (ICC = 0.75-0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75-0.87) and higher variability (CV = 47-57%). Bland-Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R-2 = 0.55-0.77; beta = 0.74-0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
