Este ítem es privado
LESCHOT GATICA, JORGE ALFONSO
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0002-0070-0475 ↗
Scopus Author ID 60236543100 ↗
ResearcherID (Web of Science) OCL-3298-2025 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
6 resultados
Publicaciones
Mostrando 1 - 6 de 6
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Multivariate Neuromuscular Profile and Principal Component Analysis: A Pilot Study in Professional Female Soccer Players(MDPI, 2026-07-28) ;ROMERO-VERA, LUIS ;ULLOA-DÍAZ, DAVID ;CONCHA-POBLETE, JONATHAN ;SANDOVAL-CÁRCAMO, MISAELCARVAJAL-PARODI, CLAUDIOBackground: Professional women's football requires precise neuromuscular characterisation because of the high mechanical demands associated with acceleration, deceleration, jumping, braking, landing, and rapid force production. The aim was to characterise the multivariate neuromuscular profile derived from the countermovement jump (CMJ) and isometric mid-thigh pull (IMTP), and to examine neuromuscular components according to tactical positions in professional female football players. Methods: Twenty-three professional female football players were assessed using the CMJ and IMTP. Force-time, impulse, rate of force development, jump performance, landing, and inter-limb imbalance variables were extracted. Principal component analysis (PCA) was applied to the standardised variables, and individual component scores were compared according to tactical positions using one-way analysis of variance (ANOVA). Results: The first five principal components explained 79.19% of the total variance. PC1 represented the propulsive force and the rate of force development; PC2 reflected total force and mechanical impulse; PC3 represented early explosiveness; PC4 grouped indicators of inter-limb imbalance; and PC5 integrated jump performance and landing control. No statistically significant differences were observed between tactical positions. Conclusions: The combination of CMJ, IMTP, and PCA enabled multiple muscle-force variables to be synthesised into interpretable neuromuscular dimensions. The findings provide preliminary and exploratory evidence to support the individual monitoring of female football players. Given the low participant-to-variable ratio, the PCA findings should be considered exploratory. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Prevalence of School Active Commuting and Associated Factors in Chilean Children: Analysis of the National Survey on Physical Activity and Sport Habits(WILEY, 2026-06-07) ;GUZMÁN‐MUÑOZ, EDUARDO ;CONCHA‐CISTERNAS, YENY; ;HERNANDEZ‐MARTINEZ, JORDÁNMERELLANO‐NAVARRO, EUGENIOBackground School active commuting is a key behavior to promote physical activity in children, yet limited evidence exists in Chile. This study examined its prevalence and associated factors among Chilean schoolchildren.Methods A cross-sectional study was conducted using data from the Chilean National Physical Activity and Sports Habits Survey, including a subsample of 1137 children aged 5-10 years derived from a nationally representative survey. School active commuting was defined as the dependent variable. Independent variables included sex, area of residence, socioeconomic status (SES), caregiver's education, self-rated health, leisure activities, and home-based physical or sedentary behaviors.Findings About one in three children (35%) reported commuting actively to school. Boys showed higher participation than girls, and active commuting was more common among children from lower SES households and among those whose caregivers had lower educational attainment. Children who preferred physical activities during leisure time were also more likely to commute actively. No differences were observed by geographic area, self-rated health, or home-based activity levels.Implications for School Health Policy, Practice, and Equity Schools and local communities should work together to ensure safe, equitable, and accessible environments that support active commuting.Conclusions Active commuting remains low in Chilean children, emphasizing the need for multisectoral policies to promote physical activity and reduce inequalities. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effects of Knee Sleeve Density on Theoretical Neuromuscular Capacities Derived from the Force-Velocity-Power Profile in the Back Squat(MDPI, 2026-01-22); ;ROMERO-VERA, LUIS ;ÑANCUPIL-ANDRADE, ALBERTO ;HERNÁNDEZ-MOSQUEIRA, CLAUDIOMOLINA-MÁRQUEZ, IVÁNBackground: Neoprene knee sleeves are commonly used to enhance joint stability and mechanical performance during resistance training. However, the specific influence of sleeve density on the force-velocity-power (F-V-P) profile during multi-joint lower-body exercises such as the back squat remains unclear. This study aimed to compare the theoretical F-V-P parameters derived from back squat performance while wearing low-density (LD) versus high-density (HD) knee sleeves. Methods: Fifteen resistance-trained males completed an incremental back squat test under both LD and HD conditions. A linear position transducer recorded barbell displacement and velocity. Individual force-velocity relationships were modelled to determine maximal theoretical force (F-0), velocity (V-0), power (Pmax), and the F-V slope. Paired-sample t-tests, linear mixed models, and Cohen's d effect sizes were calculated. Clinical relevance was assessed using a threshold defined as 0.2 x the standard deviation of the HD condition. Bayesian analyses were conducted to estimate the probability and magnitude of the observed effects. Results: No statistically significant differences were observed between sleeve conditions for F-0, V-0, Pmax, or F-V slope (p > 0.05, d <= 0.37). Nonetheless, HD sleeves yielded slightly higher mean values for F-0, V-0, and Pmax, exceeding the predefined threshold for practical relevance. Bayesian models showed moderate probabilities (similar to 0.80) that HD sleeves outperformed LD, though with limited chances of crossing the clinical significance threshold. Conclusions: Although HD sleeves do not produce systematic changes in F-V-P parameters, their increased material stiffness may provide small yet practically meaningful mechanical advantages in high-force resistance training contexts. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Integrating the Hospital Frailty Risk Score into Explainable Machine Learning to Predict Mortality in Older Adults with Pneumonia: A Chilean Population-Based Study(MDPI, 2026-05-15) ;CONCHA-CISTERNAS, YENY ;GUZMÁN-MUÑOZ, EDUARDO ;VÁSQUEZ-MUÑOZ, MANUEL ;TRONCOSO-PANTOJA, CLAUDIAFERNÁNDEZ-HUERTA, LINCOYÁNBackground/Objectives: Community-acquired pneumonia (CAP) is a leading cause of mortality in older adults. Traditional prognostic scores may underestimate risk in frail patients by assuming linear relationships between predictors and outcomes. This study aimed to develop and validate explainable machine learning models integrating the administrative Hospital Frailty Risk Score (HFRS) to predict in-hospital mortality in a nationwide cohort of older adults in Chile. Methods: A retrospective cohort study was conducted using anonymized hospital discharge records from the Chilean National Health Fund (FONASA), including 58,306 hospitalization episodes of adults aged >= 60 years across 72 public hospitals. Fourteen supervised machine learning algorithms were trained using five routinely collected predictors: age, sex, HFRS, Charlson Comorbidity Index, and length of stay. Model performance was evaluated on an independent test set using AUC-ROC. SHAP (SHapley Additive exPlanations) values were calculated to assess global and individual predictor contributions. Results: The Extra Trees classifier achieved the highest discriminative performance (AUC-ROC 0.862), outperforming logistic regression (0.642) and other linear models. SHAP analyses identified HFRS as the most influential predictor (mean |SHAP| = 0.66), followed by length of stay, age, and comorbidities. Conclusions: Ensemble tree-based models incorporating administrative frailty measures provide superior mortality prediction compared to traditional linear approaches. Frailty emerged as the primary driver of risk, supporting scalable early stratification using routinely available hospital data. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Differential Associations of the Dynamic Strength Index with Dynamic and Isometric Force Manifestations in Professional Female Soccer Players(MULTIDISCIPLINARY DIGITAL PUBLISHING INSTITUTE (MDPI), 2026-07-02) ;PÉREZ-CONTRERAS, JORGE ;VILLASECA-VICUÑA, RODRIGO ;ROMERO-VERA, LUIS; AEDO-MUÑOZ, ESTEBANBackground/Objectives: The Dynamic Strength Index (DSI) has been proposed as an indicator of the ability to dynamically express maximum available strength; however, its practical significance remains unclear. This study examined the associations of the DSI with dynamic and isometric strength measures, as well as sprint performance, in female professional soccer players. Methods: Eighteen female professional soccer players were assessed during pre-season. The DSI was calculated from peak force obtained in the countermovement jump (CMJ) and the isometric mid-thigh pull (IMTP). Spearman’s correlations were analysed alongside bootstrap confidence intervals, false discovery rate (FDR) adjustment, dependent correlation comparisons, and partial correlations controlling for body mass. Results: The DSI showed moderate unadjusted associations with relative CMJ peak force (ρ = 0.59) and relative CMJ peak yank (ρ = 0.56). However, no associations remained statistically significant after FDR correction. Despite this, the overall pattern of effect sizes and confidence intervals suggested a tendency towards stronger associations with dynamic rather than isometric variables. No meaningful associations were observed with IMTP-derived variables or sprint performance. Conclusions: In this exploratory sample, the DSI showed a tendency towards stronger associations with relative dynamic force variables than with isometric measures. However, given the lack of statistical significance after correction for multiple comparisons, these findings should be interpreted cautiously. The DSI may be better considered as a complementary metric within a broader neuromuscular assessment framework rather than as a standalone indicator. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study(MDPI, 2026-07-02) ;FUENTES-BARRÍA, HÉCTOR; ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
