Este ítem es privado
LESCHOT GATICA, JORGE ALFONSO
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0002-0070-0475 ↗
Scopus Author ID 60236543100 ↗
ResearcherID (Web of Science) OCL-3298-2025 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
2 resultados
Publicaciones
Mostrando 1 - 2 de 2
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effects of Knee Sleeve Density on Theoretical Neuromuscular Capacities Derived from the Force-Velocity-Power Profile in the Back Squat(MDPI, 2026-01-22); ;ROMERO-VERA, LUIS ;ÑANCUPIL-ANDRADE, ALBERTO ;HERNÁNDEZ-MOSQUEIRA, CLAUDIOMOLINA-MÁRQUEZ, IVÁNBackground: Neoprene knee sleeves are commonly used to enhance joint stability and mechanical performance during resistance training. However, the specific influence of sleeve density on the force-velocity-power (F-V-P) profile during multi-joint lower-body exercises such as the back squat remains unclear. This study aimed to compare the theoretical F-V-P parameters derived from back squat performance while wearing low-density (LD) versus high-density (HD) knee sleeves. Methods: Fifteen resistance-trained males completed an incremental back squat test under both LD and HD conditions. A linear position transducer recorded barbell displacement and velocity. Individual force-velocity relationships were modelled to determine maximal theoretical force (F-0), velocity (V-0), power (Pmax), and the F-V slope. Paired-sample t-tests, linear mixed models, and Cohen's d effect sizes were calculated. Clinical relevance was assessed using a threshold defined as 0.2 x the standard deviation of the HD condition. Bayesian analyses were conducted to estimate the probability and magnitude of the observed effects. Results: No statistically significant differences were observed between sleeve conditions for F-0, V-0, Pmax, or F-V slope (p > 0.05, d <= 0.37). Nonetheless, HD sleeves yielded slightly higher mean values for F-0, V-0, and Pmax, exceeding the predefined threshold for practical relevance. Bayesian models showed moderate probabilities (similar to 0.80) that HD sleeves outperformed LD, though with limited chances of crossing the clinical significance threshold. Conclusions: Although HD sleeves do not produce systematic changes in F-V-P parameters, their increased material stiffness may provide small yet practically meaningful mechanical advantages in high-force resistance training contexts. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study(MDPI, 2026-07-02) ;FUENTES-BARRÍA, HÉCTOR; ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
