CALDERÓN ARAYA, RAÚL ALEXIS

Universidad de Las Américas, Chile

Cargando...
Foto de perfil

Identificación y afiliación académica

Scopus Author ID 56341641600
ResearcherID (Web of Science) AAP-5930-2020

Vínculos académicos

Puesto de trabajo

Resultados de investigación

Publicaciones

Mostrando 1 - 3 de 3
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Tertiary treatment of domestic wastewater for reuse: Implementation and evaluation in a rural context in Chile
    (ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD, 2026-03-15)
    GONZÁLEZ, CHRISTOPHER
    ;
    NEGRETE, CONSTANZA
    ;
    DO, AURELIEN
    ;
    HERRERA, JAIME
    ;
    MARTÍNEZ DÍAZ, IVÁN
    Water scarcity in arid and semi-arid regions of Chile is intensifying demand for safe irrigation water sources. This study assesses a modular tertiary treatment train for rural wastewater reuse based on fixed-bed polishing with natural zeolite and activated carbon, followed by UV-C disinfection. Pilot-scale implementation at the La Higuera wastewater treatment plant confirmed robust field performance, reducing TSS by approximate to 70%, BOD5 by approximate to 56%, and fecal coliforms by 99.9%, enabling compliance with Chilean irrigation reuse criteria (NCh 1333; DS 90/2001). Average salinity indicators during monitoring were EC = 1774 mu S/cm and TDS = 964 mg/L, suggesting moderate irrigation restrictions and practical suitability mainly for moderately salt-tolerant crops under appropriate management (e.g., leaching and drainage). Because the pilot evaluation covered only similar to 3-4 months, long-term performance claims remain preliminary, and seasonal variability and fixed-bed media breakthrough/saturation should be validated through extended multi-season monitoring. Persisting limitations include dissolved solids control and maintaining nitrogen removal during extended operation. Overall, the proposed low-energy, locally adaptable train provides a pragmatic and transferable pathway for decentralized water reuse in arid rural settings, with site-specific adaptation mainly required for influent nitrogen loading/speciation, background salinity/TDS, and local reuse regulations, supporting circular water management aligned with SDG 6 and SDG 12.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Advanced Zeolite Composites with nZVI for Lead Removal in Mining Water: Laboratory Results and Field Validation
    (SPRINGER INT PUBL AG, 2025-07-16)
    MALDONADO, TAMARA
    ;
    MANQUIÁN-CERDA, KAREN
    ;
    FUENTEALBA, ISADORA
    ;
    ;
    RUBIO, MARÍA A.
    nZVI-functionalized zeolites were synthesized and characterized at two coating percentages: 25% (C1) and 50% (C2) w/w using FT-IR, XRD, SEM, and EM. XRD confirmed nZVI formation in the composite while SEM revealed smaller nZVI size on zeolite surfaces (C1 = 45 nm, C2 = 64 nm) than on pristine nZVI (77 nm). Pb2+ sorption was assessed on in situ synthesized nZVI-functionalized zeolites alongside the presence of the competing cation Al3+. Sorption studies showed a 60-min equilibration time for Pb2+ in composites. Pb2+ removal capacity was higher in composites than in pristine materials despite a marked decrease caused by the presence of Al3+. Composites maintained a preference for Pb2+ sorption over Al3+. The Langmuir model fits experimental data well, indicating higher Fe content in materials and increased sorption capacity and intensity for Al3+ when both cations coexisted. Nevertheless, the obtained material exhibited excellent qualities for Pb2+ removal, even in the presence of a competing element like Al3+. In addition, the water-tested materials were used in a copper mining site, which contains high concentrations of both metals. The materials displayed a similar trend to the laboratory tests, confirming their performance in complex systems, such as the water generated in mining processes.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Decoding the interfacial synergy of Fe-Cu bimetallic nanoparticles for the concurrent removal of As(V) and Cr(VI)
    (SPRINGER, 2026-04-20)
    MANQUIÁN-CERDA, KAREN
    ;
    MALDONADO, TAMARA
    ;
    CUEVAS, RUBÉN
    ;
    ;
    RUBIO, MARÍA ANGÉLICA
    Removing oxyanionic contaminants like arsenate (As(V)) and chromate (Cr(VI)) is challenging in water treatment because of their high mobility and toxicity. This study synthesised Fe-Cu bimetallic nanoparticles (BMNPs) via chemical reduction and characterised them to assess how composition affects pollutant removal. Structural analyses (SEM, TEM, XRD) showed heterogeneous nanoparticles with Fe-0, Fe3O4, Cu-0, and Cu2O phases, indicating partially oxidised Fe-Cu interfaces. Adsorption kinetics for both oxyanions fit the pseudo-second-order model, suggesting surface interactions dominate removal. Equilibrium was described by the Langmuir model for single-component systems and the Freundlich model for multicomponent systems, indicating competitive adsorption. Thermodynamic analysis showed spontaneous interactions (Delta G degrees < 0). Phosphate reduced As(V) retention, but Cr(VI) removal stayed efficient due to adsorption and partial reduction to Cr(III). The heterogeneous Fe-Cu structure affects adsorption and enables simultaneous removal of As(V) and Cr(VI) from water.