    Polysomnographic and Electromyographic Evaluation of Sleep Bruxism in Young Colombian Adults: Case-Control Study
    (MDPI, 2025-09-17)
    LÓPEZ-SOTO, OLGA PATRICIA
    ;
    ARISTIZÁBAL-HOYOS, JUAN ALBERTO
    ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    GALLÓN-BEDOYA, KAREN SOFIA
    Background: Sleep bruxism (SB) is increasingly recognized not merely as a movement disorder but as a multifactorial condition in which physiological, behavioral, and contextual factors converge. Objective: To comprehensively characterize SB in young adults, integrating polysomnography (PSG) and surface electromyography (sEMG) to describe sleep architecture, periodic limb movements (PLMs), and masticatory muscle activity; compare these parameters with matched controls; and explore clinical correlations relevant to dental practice and individualized management. Methods: Forty university adults (20 PSG-confirmed SB; 20 controls) underwent PSG assessment of total sleep time, sleep stages, arousals, apnea, oximetry, and PLMs. EMG activity of the masseter and temporalis muscles was recorded in 37 participants (18 SB, 19 controls). Statistical analyses included t-tests, Mann-Whitney U tests, and multivariate logistic regression to identify independent predictors of SB. Results: SB participants exhibited higher bruxism event counts (p <= 0.001; PS = 0.94), increased PLMs (p <= 0.01; PS = 0.75), shorter REM sleep duration (p = 0.04; d = 0.69), and higher bruxism-related arousal indices (p <= 0.001; PS = 83.4). Left masseter activity differed significantly (p = 0.03; d = 0.50), while other muscle measures showed no significant differences. Logistic regression identified age (OR = 0.59, p = 0.02), PLMs (OR = 0.96, p = 0.03), and REM sleep duration (OR = 0.98, p = 0.05) as independent predictors, explaining 58% of the variance. Conclusions: These findings provide a comprehensive profile of SB in young adults. Integrating PSG, sEMG, and oral assessments supports early diagnosis, personalized management, and interdisciplinary collaboration to prevent complications.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study
    (MDPI, 2026-07-02)
    FUENTES-BARRÍA, HÉCTOR
    ;
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study
    (MDPI, 2025-10-27)
    GARRIDO-OSORIO, VÍCTOR
    ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    SANHUEZA-GONZÁLEZ, SEBASTIÁN
    ;
    SANDOVAL-JELVES, CATARÍ
    ;
    AGUILERA-EGUÍA, RAÚL
    Background/Objectives: Low-cost portable load cell dynamometers allow for real-time assessment of muscular strength. This study evaluated the reliability and repeatability of the G-Force load cell system during isometric hip abduction and adduction in young physically active Chilean adults. Methods: In total, 24 participants (19 men, 5 women) performed two maximal voluntary contractions per movement, repeated after a 24 h interval. Measured variables included Peak Force, peak rate of force development (Peak RFD), RFD at 50, 100, and 200 ms (RFD50, RFD100, RFD200), and maximum jerk. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV%) and Bland-Altman plots. Results: Peak Force showed excellent within-day (ICC = 0.94-0.96) and high between-day reliability (ICC = 0.87-0.89; CV = 20-30%). Bland-Altman analysis indicated negligible bias for Peak Force in abduction (-6.54 N; 95% CI -19.55 to 6.47) and adduction (-17.57 N; 95% CI -37.24 to 2.09), confirming the absence of systematic error. Peak RFD, RFD50-200, and maximum Jerk showed moderate repeatability and lower between-day reliability (ICCs = 0.39-0.70; CVs = 34-57%), indicating higher variability in explosive force indices compared with maximal strength. Conclusions: The G-Force load cell reliably measures maximal isometric hip strength, while Peak RFD, RFD50-200, and maximum jerk should be interpreted cautiously. These findings support the device as a practical, low-cost tool for sports and rehabilitation, though future studies should validate dynamic indices in larger and more diverse populations.