CÓRDOVA LEÓN, KAREN VANESSA
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0003-3771-9791 ↗
Scopus Author ID 57208856816 ↗
ResearcherID (Web of Science) CLH-4623-2022 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
2 resultados
Publicaciones
Mostrando 1 - 2 de 2
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Are there differences between a real C0-C1 mobilization and a sham technique in function and pressure pain threshold in patients with chronic neck pain and upper cervical restriction? A randomised controlled clinical trial(IOS PRESS, 2023) ;ARIAS-ÁLVAREZ, GONZALO ;BUSTOS, MARIO MUÑOZ ;HIDALGO-GARCÍA, CÉSAR; PÉREZ-BELLMUNT, ALBERTBACKGROUND: Chronic neck pain is one of the main reasons for visiting a healthcare professional. In recent years, it has been shown that upper cervical restriction may be a factor involved in neck pain. OBJECTIVE: To compare the immediate effects of a real cervical mobilization technique versus a sham cervical mobilization technique in patients with chronic neck pain and upper cervical restriction. METHODS: This was a randomised, controlled, double-blind clinical trial. Twenty-eight patients with chronic neck pain were recruited and divided into two groups (14 = real cervical mobilization; 14 = sham mobilization). Both groups received a single 5-minute treatment session. Upper cervical range motion, flexion-rotation test, deep cervical activation and pressure pain threshold were measured. RESULTS: In the between-groups comparison, statistically significant differences were found in favour of the real cervical mobilization group in upper cervical extension (p = 0.003), more restricted side of flexion-rotation test (p < 0.001) and less restricted side of flexion-rotation test (p = 0.007) and in the pressure pain threshold of the right trapezius (p = 0.040) and right splenius (p = 0.049). No differences in deep muscle activation were obtained. CONCLUSION: The real cervical mobilization group generates improvements in upper cervical spine movement and pressure pain threshold of right trapezius and right splenius compared to the sham group in patients with chronic neck pain and upper cervical restriction. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Reliability of gait speed with a self-report method and a physical test method in older people from the community Fiabilidad de la velocidad de la marcha con un método autoreporte y un método de prueba física en personas mayores de la comunidad(FEDERACION ESPANOLA DE DOCENTES DE EDUCACION FISICA, 2024-03-12); ; ; ; Background: The literature increasingly emphasizes the relevance of gait speed in assessing frailty in patients aged 60 and above. However, conventional gait speed measurement may be contraindicated in situations such as trauma, in which the patient is temporarily immobile or immobilized with reduced mobility. To overcome this limitation, a numerical scale of walking speed based on The Walking Speed Questionnaire has been adapted. Objective: Assess the reliability of gait speed obtained through two methods: the numeric gait speed scale and the 10-meter walk test. Materials: The sample included 76 individuals aged 60 and above, selected from an outpatient centre in Talcahuano (Chile) through non-probabilistic convenience sampling. Participants provided self-reports of gait speed using a numeric scale proposed by Cong et al. (2016), and subsequently, the same variable was measured through the 10-meter walk test. Results: A mean gait speed of 1.17±0.26 m/s was found in the self-report and 1.15 ± 0.22 m/s in the 10 m physical test. There is a high relationship of gait speed between the self-report and the physical test (r=0.828; p>0.001), with minimal differences between them (t=0.131; p=0.193) and a very good internal consistency between both methods (Cronbach=0,914; CCI=0.818). Conclusion: The self-report of gait speed using a numerical scale with an answer in the international unit of measurement (m/s), is a reliable and effective tool to assess gait speed when the physical test is difficult to perform implement.
