Este ítem es privado
ROMERO VERA, LUIS SEBASTIÁN
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0001-9633-669X ↗
Scopus Author ID 59491928600 ↗
ResearcherID (Web of Science) LZR-8670-2025 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
4 resultados
Publicaciones
Mostrando 1 - 4 de 4
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Inter-Session Reliability of an Isometric Muscle Strength Protocol in Older Adults(MDPI, 2026-01-09) ;ANDRADES-RAMÍREZ, OSCAR ;CEBALLOS-SEPULVEDA, DOMINGO ;FUENTEALBA-MARTÍNEZ, BENJAMÍN ;VENEGAS-COFRÉ, BENJAMÍNVALENZUELA-ZIEBALLE, VÍCTORBackground: The objective of this study was to analyze the absolute and relative reliability intersession for a maximal isometric muscle strength protocol in the bilateral seated bench press (BSBP), bilateral seated row (BSR), unilateral seated knee right extension (USKER) and unilateral seated knee left extension (USKEL) in a population of older adults. Methods: Eighteen older adults (age = 69.38 +/- 5.06 years; weight = 75.79 +/- 14.18 kg; height = 1.61 +/- 0.08 m; BMI = 28.98 +/- 5.04 kg/m(2). The maximal isometric muscle strength assessment was performed in a seated position. Participants were asked to exert maximum effort during the exercise. The BSBP and BSR assessments were performed bilaterally with shoulders and elbows at 90 degrees, while the USKER and USKEL assessments were performed unilaterally. Three sets of 5 secondswere performed with a 3 minutes rest between measurements until maximum isometric strength was reached in all four measurements. Results: In the inter-session reliability measurements, acceptable absolute reliability was presented for BSR and USKER, and extremely high reliability for the BSBP and USKEL measures. In addition, extremely high relative reliability was reported for all assessments of maximum isometric muscle strength, with no significant differences were observed (p > 0.05) and an ES classified as null (ES < 0.12). Conclusions: The main results of this study show that maximal isometric muscle strength in bilateral seated bench press, bilateral seated row, and unilateral seated right and left knee extension, assessed using the Chronojump Force Sensor Kit, is reliable and reproducible for the elderly population. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Bilateral strength balance of knee extensor and flexor muscles in female soccer players(FRONTIERS MEDIA SA, 2025-10-03) ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID; ;ALFARO-CASTILLO, BRYANMUÑOZ-BUSTOS, GUSTAVOBackground: The aim of our study was analyze the bilateral strength balance of the knee extensor and flexor muscles in female soccer players. Methodology: Participated in this study twenty-three professional female soccer players. The volunteer participants of the study were eligibly if: (a) signing of informed consent, (b) 5 years of sporting experience as a soccer player and have experience with training and evaluation of muscle strength in the lower limb, (c) participate in five weekly training sessions (d) no musculoskeletal pathology in the lower limbs 6 months prior to the evaluation date. The assessment was performed unilaterally, with peak muscle strength values recorded using the FEMD device software at a constant velocity of 0.4 m s(-1). The range of motion (ROM) was 90 degrees-0 degrees of joint extension in the sitting position and 150 degrees-90 degrees of flexion in the prone position. Each participant was required to perform their maximum effort for all repetitions. Results: Bilateral strength balance measurements were obtained in the range of 10.68%-13.80% for maximum muscle strength in knee extension and 13.27%-15.21%. No significant differences (p > 0.05) were found in the comparison of independent means for maximum muscle strength between the knee extension and flexion in the concentric and eccentric phases. Significant differences (p < 0.01) and small ES (ES < 3.32) were found in peak muscle strength measurements of the dominant and non-dominant lower extremity in the unilateral comparison of the extensor muscle and the flexor muscle group in the concentric and eccentric phase. Conclusion: In the analysis of bilateral strength balance, lower indices are presented in the knee extensor compared to the flexor, these bilateral indices would reveal intrinsic and extrinsic risk factors for musculoskeletal injuries in the hamstring muscles and anterior cruciate ligament of professional soccer players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effect of a muscle strength training program on the gait test and dynamic balance in older adults: a pilot study(UNIV MALAGA, 2026-06-30) ;ANDRADES-RAMÍREZ, OSCAR ;ALFARO CASTILLO, BRYAN; ;CASTILLO-QUEZADA, HUMBERTOSEGUEL-LÓPEZ, MARÍAOlder adults (OA) constitute a rapidly growing age group in the current population, posing a global challenge that impacts the economy and public health. The objective of this study was to analyze the effect of a muscle strength program at 60% of 1RM on the 6-minute walk test and the stand-up-and-walk test in OA. Eleven OA participants took part in an 8-week muscle strength program with three 45-minute sessions per week, consisting of three sets of 6-8 repetitions with 2 minutes and 30 seconds of rest between sets. The training program resulted in significant increases in strength assessments (p < 0.003-p < 0.005). Additionally, in the 6-minute walk test, an increase in distance covered and a significant decrease (p < 0.02) in timed-up-and-go test time were reported. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study(MDPI, 2025-11-22); ;FUENTES-BARRÍA, HÉCTOR ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 +/- 4.97 years; body mass index: 25.79 +/- 3.02 kg/m(2)) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland-Altman analysis and Pearson's correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86-0.91) and moderate-to-good inter-platform reliability (ICC = 0.75-0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75-0.87) and higher variability (CV = 47-57%). Bland-Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R-2 = 0.55-0.77; beta = 0.74-0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
