HUERTA OJEDA, ÁLVARO CRISTIAN
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0001-6871-098X ↗
Scopus Author ID 57192837821 ↗
ResearcherID (Web of Science) AAE-7104-2021 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
5 resultados
Publicaciones
Mostrando 1 - 5 de 5
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Six-minute rowing test: a valid and reliable method for assessing power output in amateur male rowers(PEERJ INC, 2022-09-22); ;RIQUELME GUERRA, MIGUEL ;CORONADO ROMÁN, WALTER; FUENTES-KLOSS, RODRIGOBackground: Standardized tests are currently available to assess power output in elite rowers. However, there are no valid and reliable tests to assess power output in amateur rowers. Objective: This study aimed to determine the validity and reliability of a 6-min rowing ergometer test (6-minRT) as a predictor of power output (PO) in amateur male rowers. Methods: Twelve male amateur rowers were part of the study. All participants were instructed to perform an incremental test (IT), a 6-minRT test, and a retest. The validity of the 6-minRT was determined by comparing maximum oxygen uptake (VO2max) and power output (PO) between the IT and 6-minRT. Reliability included the coefficient of variation (CV), intra-class correlation coefficient (ICC), and mean standard error between the 6-minRT test and retest. The significance level was p < 0.05. Results: There was no significant difference in VO2max in both IT and 6-minRT (p = 0.18), while the mean power output (Pmean) generated in the 6-minRT equaled 91.96% of the maximal aerobic power (MAP) generated in the IT (p = 0.004). Reliability analysis for the 6-minRT showed a CV = 0.50% and ICC = 0.97 for distance, a CV = 1.85% and ICC = 0.96 for Pmean. Conclusion: From a ventilatory and mechanical point of view, the 6-minRT is a maximally valid test for establishing MAP in amateur rowers. Also, the 6-minRT evidences a high degree of agreement between days. Therefore, the 6-minRT is a valid and reliable test for assessing PO in amateur male rowers. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Lepidium Meyenii Walp. (Maca) and Blood Biomarkers of Muscle Damage and Post-Exertion Protein Degradation: A Systematic Review and Meta-Analysis of Preclinical Studies(MDPI, 2026-06-20) ;RODRÍGUEZ ROJAS, JAVIERA; ;BARAHONA-FUENTES, GUILLERMO ;JORQUERA-AGUILERA, CARLOSCANCINO-LÓPEZ, JORGEBackground: Lepidium meyenii Walp (L. meyenii), traditionally known as maca, is widely recognized for its health-promoting properties, including potential protection against exercise-induced muscle damage (EIMD). However, its precise effect on post-exercise blood biomarkers remains unclear. Objective: This study aimed to qualitatively review research published until April 2026 examining L. meyenii supplementation to reduce blood markers of muscle damage and protein degradation post-exertion in animal studies. Specifically, the effect size (ES) of L. meyenii supplementation on post-exercise levels of creatine kinase (CK), lactate dehydrogenase (LDH), and blood urea nitrogen (BUN) was estimated. Methods: This systematic review and meta-analysis were conducted in accordance with the PRISMA guidelines. The certainty of the evidence was assessed using the GRADE framework. Relevant studies were identified through Web of Science, Scopus, SPORTDiscus, PubMed, and MEDLINE. Eligible studies included in vivo experiments in animals with controlled designs and pre-/post-intervention assessments. Methodological quality and risk of bias were evaluated using the CAMARADES tool. Statistical analysis involved standardized mean differences (SMD) using Hedges' g with 95% confidence intervals. Results: 15 studies were included in the systematic review, and 14 studies in animals in the meta-analysis. The CAMARADES scores ranged from 5 to 7 points, indicating moderate methodological quality. Supplementation with L. meyenii was not associated with statistically significant changes in LDH (SMD = -1.37; 95% CI -3.34 to 0.59), BUN (SMD = -0.37; 95% CI -2.16 to 1.42) nor CK (SMD = 0.29; 95% CI -5.45 to 6.03), with very high heterogeneity (I2 > 97%). Exploratory subgroup analyses and meta-regression analyses by formulation type and dose did not identify any moderators that could robustly explain this heterogeneity. Conclusions: The available evidence does not support a robust overall effect of L. meyenii supplementation on blood biomarkers of muscle damage or protein catabolism in animals subjected to physical stress. The high degree of heterogeneity could not be robustly explained by either the type of formulation or the dose. These findings, which are exploratory and hypothesis-generating in nature, highlight the need for standardized, well-characterized formulations and trials with adequate statistical power. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode(SAGE PUBLICATIONS INC, 2024-04-27); ; ; BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effect of an Intra-Sets Variable Resistance Potentiation Protocol on Throwing Speed in Elite Female Handball Players(MDPI, 2025-03-25); ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID; BARAHONA-FUENTES, GUILLERMOThe peak velocity of an athlete's throws is a determining factor for sports performance. The aim of this study was to analyze the effects of a post-activation performance enhancement (PAPE) protocol with functional electro-mechanical dynamometry (FEMD) on throwing velocity. Thirteen international-level female handball players voluntarily participated in the study. The PAPE protocol considered four sets of eight repetitions controlled by FEMD (four at 30% of 1RM followed by another four at 60% of 1RM). After each series, the athletes' throwing velocity was measured. Significant differences (p < 0.01) were found in the effect size (ES), which measures the strength of the statistical relationship between two variables by group with the repeated measures ANOVA statistic with an effect size omega 2 = 0.028. The effect size analysis identified measurements that are considered null for the baseline-PAPE 1 comparison and small baseline-PAPE 2, baseline-PAPE 3, and baseline-PAPE 4. When resistance is controlled during the run as with an FEMD device, only two sets of eight repetitions (four repetitions at 30% and four repetitions at 60% of 1RM) are required for the improvement of throwing speed in elite handball players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Variable Resistance—An Efficient Method to Generate Muscle Potentiation: A Systematic Review and Meta-Analysis(MDPI, 2023-02-28); ; ; ; CHIROSA-RÍOS, LUIS JAVIERVariable resistance (VR) is a methodology that has shown good results in developing muscular strength and power. However, no updated information relates to the use of VR as an activation to trigger post-activation performance enhancement (PAPE). The primary objective of this systematic review and meta-analysis was to review and qualitatively describe studies published between 2012 and 2022 that used VR to generate PAPE in muscle power-dominant sports. The secondary objective was to calculate the effect size of the different power outcomes reported in the selected studies. The search was designed following the PRISMA® guidelines for systematic reviews and meta-analyses and performed in the Web of Science (WOS), Scopus, SPORTDiscus, PubMed, and MEDLINE between 2012 and 2022. The methodological quality and risk of bias were evaluated with the Cochrane Collaboration tool. The main variables were the throwing speed, time in sprint tests, and jump height. The analysis was conducted with a pooled standardized mean difference (SMD) through a Hedges’ g test (95% CI). Twenty-two studies were included in the systematic review and ten in the meta-analysis, revealing a trivial effect for throwing speed (SMD = 0.06; CI = 95%: −0.23–0.35; p = 0.69), a small effect for the time in sprint tests (SMD = −0.37; CI = 95%: −0.72–−0.02; p = 0.04), and a moderate effect for jump height (SMD = 0.55; CI = 95%: 0.29–0.81; p ˂ 0.0001). All forms of VR used for neuromuscular activation effectively triggered PAPE. Specifically, the results showed that activation with VR generates performance increases in time, in sprint tests and jump height, and a trivial effect in throwing tests (speed and distance).
