HUERTA OJEDA, ÁLVARO CRISTIAN
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0001-6871-098X ↗
Scopus Author ID 57192837821 ↗
ResearcherID (Web of Science) AAE-7104-2021 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
15 resultados
Publicaciones
Mostrando 1 - 10 de 15
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Six-minute rowing test: a valid and reliable method for assessing power output in amateur male rowers(PEERJ INC, 2022-09-22); ;RIQUELME GUERRA, MIGUEL ;CORONADO ROMÁN, WALTER; FUENTES-KLOSS, RODRIGOBackground: Standardized tests are currently available to assess power output in elite rowers. However, there are no valid and reliable tests to assess power output in amateur rowers. Objective: This study aimed to determine the validity and reliability of a 6-min rowing ergometer test (6-minRT) as a predictor of power output (PO) in amateur male rowers. Methods: Twelve male amateur rowers were part of the study. All participants were instructed to perform an incremental test (IT), a 6-minRT test, and a retest. The validity of the 6-minRT was determined by comparing maximum oxygen uptake (VO2max) and power output (PO) between the IT and 6-minRT. Reliability included the coefficient of variation (CV), intra-class correlation coefficient (ICC), and mean standard error between the 6-minRT test and retest. The significance level was p < 0.05. Results: There was no significant difference in VO2max in both IT and 6-minRT (p = 0.18), while the mean power output (Pmean) generated in the 6-minRT equaled 91.96% of the maximal aerobic power (MAP) generated in the IT (p = 0.004). Reliability analysis for the 6-minRT showed a CV = 0.50% and ICC = 0.97 for distance, a CV = 1.85% and ICC = 0.96 for Pmean. Conclusion: From a ventilatory and mechanical point of view, the 6-minRT is a maximally valid test for establishing MAP in amateur rowers. Also, the 6-minRT evidences a high degree of agreement between days. Therefore, the 6-minRT is a valid and reliable test for assessing PO in amateur male rowers. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Block strength training based on age-related functional consequences in older women(PUBLIC LIBRARY SCIENCE, 2025-05-30) ;JOFRÉ-SALDÍA, EMILIO ;FESTA, RAÚL RICARDO ;VILLALOBOS-GORIGOITÍA, ÁLVARO ;JORQUERA-AGUILERA, CARLOSStrength training is a form of healthy ageing in older women. Although recommendations currently exist, some are very broad or fail to cover the needs of aging. Therefore, the purpose of this study was to analyze the effects of blocks strength training based on age-related functional consequences on functional performance in older adult women. 82 community-dwelling older women (70.17 +/- 6.04 y) were randomly assigned to either experimental (n = 40) or control (n = 42) group. Experimental group performed a Block Strength Training (BST) program based on strength, power, and muscular endurance, and different level of effort for 9 weeks, and control maintained daily routine with physical activity recommendations. Functional performance was assessed using absolute handgrip strength [AHS], timed up and go [TUG], two-minutes step test [2MST], five times stand-to-sit test [5-SST], 6-m walking speed test [6-WS] pre-post intervention. Statistical analyses were performed using two-way ANOVA (Time*Group) and effect size (partial eta-squared, & eng;P2) with a significance level of p < 0.05. BST improved functional performance in the protocols of AHS (21.51 vs. 23.07-kg; + 7%), TUG (8.22 vs. 7.29-sec; + 11%), 2MST (78.76 vs. 97.18-steps; + 23%), 5-SST (12.68 vs. 9.43-sec; + 26%), and 6-WS (1.16 vs. 1.36- ms(-1); + 17%) compared to control (19.31 vs. 19.66-kg; 8.94 vs. 9.26-sec; 62.68 vs. 63.73-steps; 13.99 vs. 14.25-sec; 1.06 vs. 1.06-ms(-1), respectively) in a Time*Group interaction effect (p < 0.01; & eng;P2( )> 0.11). This BST is effective in improving overall functional performance and thus reducing the risk of physical frailty in community-dwelling older women. These findings strengthen the approach to exercise programming over recommendations, moving toward effective precision dosing for older adults. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode(SAGE PUBLICATIONS INC, 2024-04-27); ; ; BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men(PEERJ INC, 2026-07-15); ;BARAHONA-FUENTES, GUILLERMO; ;JORQUERA-AGUILERA, CARLOSBackground Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Relationship between Asymmetries and Functional Autonomy in Older Chilean Adults(MDPI, 2022-11-16); ;TORO-ZEPEDA, VANIESKA ;JOFRÉ-SALDÍA, EMILIO ;BRAVO, MAXIMILIANOPARRA, CAROLThe objectives of this study were: (a) to determine asymmetries, both lower limb (LL) and upper limb (UL), in Chilean older adults, and (b) to relate asymmetries to FA in both LL and UL. Forty-one older adults voluntarily participated in this study (mean +/- standard deviation [SD]: age 72.0 +/- 8.0 years, LL asymmetries 13.78 +/- 14.87%, UL asymmetries 10.70 +/- 8.85%, FA 40.35 +/- 16.26 points). The variables were: (1) asymmetries of LL and UL, assessed through a force platform and handgrip, respectively; (2) FA, assessed through the Latin American Group for Maturity (GDLAM) and the GDLAM index of autonomy (GI) protocol. The relationship between the variables was performed through Spearman's correlation. The analysis showed that 39% of the participants presented asymmetries above 15% in the LL. Likewise, this 39% of older adults presented a lower FA than their peers with asymmetries below 15% in the LL (<= 15%: 35.64 +/- 12.26 points vs. >15%: 47.69 +/- 19.23 points, p = 0.003). The analysis showed a small correlation between LL and GI asymmetries (r = 0.27, p = 0.07) and a small but negative correlation between UL and GI (r = -0.21). The mean values of asymmetries of both LL and UL are within 'normal' parameters. However, several older adults were identified as being at risk. In parallel, older adults who presented a higher level of asymmetries in LL showed a lower level of FA. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Six-minute rowing test: a practical tool for training prescription, from ventilatory thresholds and power outputs, in amateur male rowers(PEERJ INC, 2023-09-29); ;RIQUELME GUERRA, MIGUEL ;Universidad de Las Americas - Chile ;Universidad MayorUniversidad Santo TomasBackground. The 6-minute rowing ergometer test (6-minRT) is valid and reliable for establishing maximal aerobic power (MAP) in amateur male rowers. However, ventilatory thresholds (VTs) have not yet been established with their mechanical correspondence in this test. Objective. The primary objective was to determine the VTs in the 6-minRT achieved by amateur male rowers, while the secondary objective was to determine the correspondence between ventilatory, mechanical, and heart rate (HR) outcomes of the 6-minRT. Methods. Sixteen amateur male rowers were part of the study. All participants were instructed to perform an incremental test (IT) and a 6-minRT. Determination of the ventilatory parameters for the first ventilatory threshold (VT1), the second ventilatory threshold (VT2), and 6minRTVO2max were performed by correlating the outcomes of VT1, VT2, and VO2max obtained in the IT, with the outcomes of 6-minRT. For these purposes, Pearson's test was used, with the following criteria: trivial, 0.1; small, 0.1- 0.3; moderate, 0.3-0.5; high, 0.5-0.7; very high, 0.7-0.9; or practically perfect, 0.9. The significance level wasp < 0.05. Results. The IT analysis determined that VT1 and VT2 correspond to 55 and 80% of VO2max , respectively. A high correlation was observed between IT outcomes in VT1, VT2, and VO2max , with the outcomes of 6-minRT (r > 0.6). Conclusion. Based on IT ventilatory parameters and concordance analysis, VT1 and VT2 of 6-minRT are determined at 55 and 80%, respectively, of both ventilatory parameters and their corresponding mechanical outcomes and HR. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Incidence of Muscular Strength, Anthropometry, and Asymmetry in the General Index of Autonomy in Older Chilean Women Incidencia de la Fuerza Muscular, Antropometría y Asimetría en el Índice General de Autonomía en Mujeres Mayores Chilenas(UNIVERSIDAD DE LA FRONTERA, 2024-04-01) ;JOFRÉ-SALDÍA, EMILIO; ;ARRIAGADA-MOLINA, JIMENA ;VILLALOBOS-GORIGOITÍA, ÁLVAROVALLADARES-IDE, DENISSEFrailty affects the functional autonomy (FA) of older adults and could manifest itself in muscle imbalances in the limbs, resulting in a disparity in size and strength between them. In Chile, information on the relationship between muscle strength (MS) levels and FA asymmetries in older women is limited. This study related the levels of MS, anthropometric parameters, and asymmetries of the lower and upper limbs, with the FA of a group of older Chilean women. The study included 39 women who participated, and their FA was evaluated using the GDLAM index (IG). Based on the score obtained in the IG, they were classified by percentiles as Group 1 with favorable FA (P ≤ 50) and Group 2 with low FA (P > 50). Anthropometric parameters were BMI, fat percentage, bone mass, circumferences (arm, thigh, calf), diameters (humerus, femur) and upper/lower limb strength was evaluated to determine asymmetries. The differences between the covariates of both groups were evaluated using the student’s t test and the Mann-Whitney test for independent samples. G1 presented less asymmetry (p > 0.05) in the lower limbs and greater calf circumference than G2 (p < 0.05). G1 presented greater bilateral strength (dominant and non-dominant limb) compared to G2 (p < 0.05). The covariates of age, anthropometry, MS, and lower/upper limb asymmetries influence FA in older women. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Test-retest reliability of Latin American Group for Maturity (GDLAM) protocol in older women(PUBLIC LIBRARY SCIENCE, 2024-04-19); ;JOFRÉ-SALDÍA, EMILIO ;ARRIAGADA MOLINA, JIMENA; PARADA TOLEDO, MARÍA PAZFunctional autonomy (FA) is a critical factor in determining the quality of life of older adults (OA), especially in the case of older women (OW), as they face a decline in FA in their later years of life. FA should be assessed early, using valid, reliable, and low-cost tests. This study evaluated the test-retest reliability of GDLAM and GDLAM autonomy index (GI) in OW. Thirty-nine OW (71.2 +/- 6.50 years) participated in the study. A repeated measures design was used to compare the interday test-retest reliability of the five GDLAM tests (seconds) and the GI (points). The five tests represent activities of daily living, such as dressing or wandering around the house, while the GI provides a weighting of the results of the five tests. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. The outcome of the five tests, represented by the GI, showed high interday test-retest reliability (CV = 6.00% and ICC = 0.91). The results of this study demonstrate that the five tests of the GDLAM protocol and the GI have high interday test-retest reliability and good interday reproducibility. From a practical point of view, the GDLAM protocol allows the assessment of FA of community-dwelling OW, providing background for early diagnosis and, with it, the possibility of developing an individualized physical exercise prescription. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Analysis and stratification of internal and external loads in rowers of different categories, age groups, and sex: a systematic review and meta-analysis(UNIVERSIDADE ESTADUAL PAULISTA - UNESP, 2025-04-16); ;RIQUELME GUERRA, MIGUEL; ; MARTÍNEZ-GARCÍA, DARÍOBackground Competitive rowing has also been on the Olympic program since the first Modern Olympic Games. However, there are no reports that normalize physical performance in the different tests. Aim: The purpose of the study was to analyze and present standardized values of physical performance in rowers of different categories, age groups, and sex. Methods: The search was structured under the PRISMA® guidelines for systematic reviews and meta-analysis. The search was performed in Web of Science, Scopus, SPORTDiscus, PubMed, and MedLine with no time limit until September 2023. Variables analyzed were maximal oxygen consumption (VO2max), heart rate, aerobic power, anaerobic power, and critical rowing speeds. Results: Most studies focus on VO2max. The highest VO2max was in the “elite” men category (5.46 LO2·min-1), while the lowest value was in the “novice” women category (2.88 LO2·min-1). The most frequently used test to evaluate VO2max was the 2,000-meter (m) rowing ergometer. Conclusion: The internal load most evaluated in rowers of all categories, age groups, and sex is VO2max. In most cases, VO2max is evaluated through the 2,000 m rowing ergometer test. However, this test has low reliability in lower-level athletes. In the latter case, exploring tests with a shorter duration (6-min on the rowing ergometer) is suggested. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Latin American Group for Maturity (GDLAM) protocol: a reliable method to assess the functional autonomy of community-dwelling older men(PEERJ INC, 2026-05-29); ;GALDAMES MALIQUEO, SERGIO ;VALDERRAMA MUÑOZ, MARCELA; Background. Functional autonomy (FA) in older adults can be assessed using the Latin American Group for Maturity Protocol (GDLAM). However, the nter-day reliability of the GDLAM protocol and its General Index of Functional Autonomy (GI) has not been determined in community-dwelling older men (OM). Objective. To determine the inter-day reliability of the GDLAM protocol and the GI in OM, considering the effect of age on these parameters. Materials and methods. Fifty OM participated, divided into two age groups (All: 73.9 +/- 6.9 years; G1 < 75 years: n = 30, 69.2 +/- 3.6 years; G2 >= 75 years: n = 20, 81.0 +/- 3.9 years). A repeated measures design was used to analyze the inter-day reliability of the five functional tests of the GDLAM protocol (in seconds) and the GI (in points). The statistical analysis included the intraclass correlation coefficient (ICC) and the coefficient of variation (CV). Reliability was considered acceptable when CV <= 10% and ICC >= 0.80, and high when CV <= 5% and ICC >= 0.90. Results. The overall analysis and analysis by age group showed high inter-day reliability (All: CV = 4.38%, ICC = 0.91; G1: CV = 3.35%, ICC = 0.93; G2: CV = 4.33%, ICC = 0.92). Conclusion. The GDLAM protocol and GI show high inter-day reliability and reproducibility, supporting their use to assess FA in community-dwelling older adults.
