HUERTA OJEDA, ÁLVARO CRISTIAN
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0001-6871-098X ↗
Scopus Author ID 57192837821 ↗
ResearcherID (Web of Science) AAE-7104-2021 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
2 resultados
Publicaciones
Mostrando 1 - 2 de 2
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Six-minute rowing test: a valid and reliable method for assessing power output in amateur male rowers(PEERJ INC, 2022-09-22); ;RIQUELME GUERRA, MIGUEL ;CORONADO ROMÁN, WALTER; FUENTES-KLOSS, RODRIGOBackground: Standardized tests are currently available to assess power output in elite rowers. However, there are no valid and reliable tests to assess power output in amateur rowers. Objective: This study aimed to determine the validity and reliability of a 6-min rowing ergometer test (6-minRT) as a predictor of power output (PO) in amateur male rowers. Methods: Twelve male amateur rowers were part of the study. All participants were instructed to perform an incremental test (IT), a 6-minRT test, and a retest. The validity of the 6-minRT was determined by comparing maximum oxygen uptake (VO2max) and power output (PO) between the IT and 6-minRT. Reliability included the coefficient of variation (CV), intra-class correlation coefficient (ICC), and mean standard error between the 6-minRT test and retest. The significance level was p < 0.05. Results: There was no significant difference in VO2max in both IT and 6-minRT (p = 0.18), while the mean power output (Pmean) generated in the 6-minRT equaled 91.96% of the maximal aerobic power (MAP) generated in the IT (p = 0.004). Reliability analysis for the 6-minRT showed a CV = 0.50% and ICC = 0.97 for distance, a CV = 1.85% and ICC = 0.96 for Pmean. Conclusion: From a ventilatory and mechanical point of view, the 6-minRT is a maximally valid test for establishing MAP in amateur rowers. Also, the 6-minRT evidences a high degree of agreement between days. Therefore, the 6-minRT is a valid and reliable test for assessing PO in amateur male rowers. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Test-retest reliability of Latin American Group for Maturity (GDLAM) protocol in older women(PUBLIC LIBRARY SCIENCE, 2024-04-19); ;JOFRÉ-SALDÍA, EMILIO ;ARRIAGADA MOLINA, JIMENA; PARADA TOLEDO, MARÍA PAZFunctional autonomy (FA) is a critical factor in determining the quality of life of older adults (OA), especially in the case of older women (OW), as they face a decline in FA in their later years of life. FA should be assessed early, using valid, reliable, and low-cost tests. This study evaluated the test-retest reliability of GDLAM and GDLAM autonomy index (GI) in OW. Thirty-nine OW (71.2 +/- 6.50 years) participated in the study. A repeated measures design was used to compare the interday test-retest reliability of the five GDLAM tests (seconds) and the GI (points). The five tests represent activities of daily living, such as dressing or wandering around the house, while the GI provides a weighting of the results of the five tests. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. The outcome of the five tests, represented by the GI, showed high interday test-retest reliability (CV = 6.00% and ICC = 0.91). The results of this study demonstrate that the five tests of the GDLAM protocol and the GI have high interday test-retest reliability and good interday reproducibility. From a practical point of view, the GDLAM protocol allows the assessment of FA of community-dwelling OW, providing background for early diagnosis and, with it, the possibility of developing an individualized physical exercise prescription.
