HUERTA OJEDA, ÁLVARO CRISTIAN

Universidad de Las Américas, Chile

Cargando...
Foto de perfil

Identificación y afiliación académica

Scopus Author ID 57192837821
ResearcherID (Web of Science) AAE-7104-2021

Vínculos académicos

Puesto de trabajo

Resultados de investigación

Publicaciones

Mostrando 1 - 5 de 5
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Block strength training based on age-related functional consequences in older women
    (PUBLIC LIBRARY SCIENCE, 2025-05-30)
    JOFRÉ-SALDÍA, EMILIO
    ;
    FESTA, RAÚL RICARDO
    ;
    VILLALOBOS-GORIGOITÍA, ÁLVARO
    ;
    JORQUERA-AGUILERA, CARLOS
    ;
    Strength training is a form of healthy ageing in older women. Although recommendations currently exist, some are very broad or fail to cover the needs of aging. Therefore, the purpose of this study was to analyze the effects of blocks strength training based on age-related functional consequences on functional performance in older adult women. 82 community-dwelling older women (70.17 +/- 6.04 y) were randomly assigned to either experimental (n = 40) or control (n = 42) group. Experimental group performed a Block Strength Training (BST) program based on strength, power, and muscular endurance, and different level of effort for 9 weeks, and control maintained daily routine with physical activity recommendations. Functional performance was assessed using absolute handgrip strength [AHS], timed up and go [TUG], two-minutes step test [2MST], five times stand-to-sit test [5-SST], 6-m walking speed test [6-WS] pre-post intervention. Statistical analyses were performed using two-way ANOVA (Time*Group) and effect size (partial eta-squared, & eng;P2) with a significance level of p < 0.05. BST improved functional performance in the protocols of AHS (21.51 vs. 23.07-kg; + 7%), TUG (8.22 vs. 7.29-sec; + 11%), 2MST (78.76 vs. 97.18-steps; + 23%), 5-SST (12.68 vs. 9.43-sec; + 26%), and 6-WS (1.16 vs. 1.36- ms(-1); + 17%) compared to control (19.31 vs. 19.66-kg; 8.94 vs. 9.26-sec; 62.68 vs. 63.73-steps; 13.99 vs. 14.25-sec; 1.06 vs. 1.06-ms(-1), respectively) in a Time*Group interaction effect (p < 0.01; & eng;P2( )> 0.11). This BST is effective in improving overall functional performance and thus reducing the risk of physical frailty in community-dwelling older women. These findings strengthen the approach to exercise programming over recommendations, moving toward effective precision dosing for older adults.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men
    (PEERJ INC, 2026-07-15) ;
    BARAHONA-FUENTES, GUILLERMO
    ;
    ;
    JORQUERA-AGUILERA, CARLOS
    ;
    Background Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Analysis and stratification of internal and external loads in rowers of different categories, age groups, and sex: a systematic review and meta-analysis
    (UNIVERSIDADE ESTADUAL PAULISTA - UNESP, 2025-04-16) ;
    RIQUELME GUERRA, MIGUEL
    ;
    ; ;
    MARTÍNEZ-GARCÍA, DARÍO
    Background Competitive rowing has also been on the Olympic program since the first Modern Olympic Games. However, there are no reports that normalize physical performance in the different tests. Aim: The purpose of the study was to analyze and present standardized values of physical performance in rowers of different categories, age groups, and sex. Methods: The search was structured under the PRISMA® guidelines for systematic reviews and meta-analysis. The search was performed in Web of Science, Scopus, SPORTDiscus, PubMed, and MedLine with no time limit until September 2023. Variables analyzed were maximal oxygen consumption (VO2max), heart rate, aerobic power, anaerobic power, and critical rowing speeds. Results: Most studies focus on VO2max. The highest VO2max was in the “elite” men category (5.46 LO2·min-1), while the lowest value was in the “novice” women category (2.88 LO2·min-1). The most frequently used test to evaluate VO2max was the 2,000-meter (m) rowing ergometer. Conclusion: The internal load most evaluated in rowers of all categories, age groups, and sex is VO2max. In most cases, VO2max is evaluated through the 2,000 m rowing ergometer test. However, this test has low reliability in lower-level athletes. In the latter case, exploring tests with a shorter duration (6-min on the rowing ergometer) is suggested.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Latin American Group for Maturity (GDLAM) protocol: a reliable method to assess the functional autonomy of community-dwelling older men
    (PEERJ INC, 2026-05-29) ;
    GALDAMES MALIQUEO, SERGIO
    ;
    VALDERRAMA MUÑOZ, MARCELA
    ;
    ;
    Background. Functional autonomy (FA) in older adults can be assessed using the Latin American Group for Maturity Protocol (GDLAM). However, the nter-day reliability of the GDLAM protocol and its General Index of Functional Autonomy (GI) has not been determined in community-dwelling older men (OM). Objective. To determine the inter-day reliability of the GDLAM protocol and the GI in OM, considering the effect of age on these parameters. Materials and methods. Fifty OM participated, divided into two age groups (All: 73.9 +/- 6.9 years; G1 < 75 years: n = 30, 69.2 +/- 3.6 years; G2 >= 75 years: n = 20, 81.0 +/- 3.9 years). A repeated measures design was used to analyze the inter-day reliability of the five functional tests of the GDLAM protocol (in seconds) and the GI (in points). The statistical analysis included the intraclass correlation coefficient (ICC) and the coefficient of variation (CV). Reliability was considered acceptable when CV <= 10% and ICC >= 0.80, and high when CV <= 5% and ICC >= 0.90. Results. The overall analysis and analysis by age group showed high inter-day reliability (All: CV = 4.38%, ICC = 0.91; G1: CV = 3.35%, ICC = 0.93; G2: CV = 4.33%, ICC = 0.92). Conclusion. The GDLAM protocol and GI show high inter-day reliability and reproducibility, supporting their use to assess FA in community-dwelling older adults.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    PRETIE-Q Spanish Version and Affective-Functional Responses to Age-Based Strength Training in Older Women: An Exploratory Study
    (MDPI, 2025-11-21)
    JOFRÉ-SALDÍA, EMILIO
    ;
    FESTA, RAÚL RICARDO
    ;
    ;
    CANDIA, ALEJANDRO A.
    ;
    FARIAS-VALENZUELA, CLAUDIO
    Background: To promote exercise adherence, programs should consider not only functional effects but also a comprehensive affective response. This study analyzed the affective responses and functional performance in an age-based Block Strength Training (BST) for older women. Methods: Twenty-eight community-dwelling and Spanish-speaking older women participated in this study (age 68.39 +/- 5.95 years) performed a 12-week age-based BST. Preference for and Tolerance of the Intensity of Exercise Questionnaire Spanish version (PRETIE-Q-Sv) was measured before and after each block four times. Additionally, Feeling Scale (FS) and Rating of Perceived Exertion session (sRPE) were measured. Functional performance was assessed before and after the BST using Timed Up and Go, Two-Minutes Step Test, and Five Times Stand-to-Sit Test. Statistical analyses included Cronbach's alpha (alpha), Spearman's (rho, rho) and Pearson's (r) coefficients, repeated-measures ANOVA or Friedman, and Paired comparison. The significance level was set at p < 0.05. Results: The PRETIE-Q-Sv showed acceptable internal consistency for both Preference (alpha = 0.80) and Tolerance (alpha = 0.78) constructs, with most items showing reliability with their construct scores (rho >= 0.50). Preference remained stable (F (2.39, 64.59) = 2.64, p = 0.070, eta(2)(p) = 0.09), and Tolerance increased (F (2.09, 56.35) = 11.84, p < 0.001, eta(2)(p) = 0.30)., with overall average scores close to 22. These were not related to FS or sRPE (rho/r = -0.02 to 0.14). All functional performance tests showed significant improvement after the BST (p < 0.001, d/r(b) > 0.80). Conclusions: The PRETIE-Q-Sv adapted well to the language. Preference and Tolerance remained at intermediate levels, with BST programming aligned to individual tendencies and showing no association with FS or sRPE, whereas the increase in Tolerance suggests that BST enhances older women's ability to persist under uncomfortable effort. Improvements in functional performance support the effectiveness of the BST as a precision exercise dose.