HUERTA OJEDA, ÁLVARO CRISTIAN
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0001-6871-098X ↗
Scopus Author ID 57192837821 ↗
ResearcherID (Web of Science) AAE-7104-2021 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
6 resultados
Publicaciones
Mostrando 1 - 6 de 6
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Six-minute rowing test: a valid and reliable method for assessing power output in amateur male rowers(PEERJ INC, 2022-09-22); ;RIQUELME GUERRA, MIGUEL ;CORONADO ROMÁN, WALTER; FUENTES-KLOSS, RODRIGOBackground: Standardized tests are currently available to assess power output in elite rowers. However, there are no valid and reliable tests to assess power output in amateur rowers. Objective: This study aimed to determine the validity and reliability of a 6-min rowing ergometer test (6-minRT) as a predictor of power output (PO) in amateur male rowers. Methods: Twelve male amateur rowers were part of the study. All participants were instructed to perform an incremental test (IT), a 6-minRT test, and a retest. The validity of the 6-minRT was determined by comparing maximum oxygen uptake (VO2max) and power output (PO) between the IT and 6-minRT. Reliability included the coefficient of variation (CV), intra-class correlation coefficient (ICC), and mean standard error between the 6-minRT test and retest. The significance level was p < 0.05. Results: There was no significant difference in VO2max in both IT and 6-minRT (p = 0.18), while the mean power output (Pmean) generated in the 6-minRT equaled 91.96% of the maximal aerobic power (MAP) generated in the IT (p = 0.004). Reliability analysis for the 6-minRT showed a CV = 0.50% and ICC = 0.97 for distance, a CV = 1.85% and ICC = 0.96 for Pmean. Conclusion: From a ventilatory and mechanical point of view, the 6-minRT is a maximally valid test for establishing MAP in amateur rowers. Also, the 6-minRT evidences a high degree of agreement between days. Therefore, the 6-minRT is a valid and reliable test for assessing PO in amateur male rowers. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode(SAGE PUBLICATIONS INC, 2024-04-27); ; ; BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men(PEERJ INC, 2026-07-15); ;BARAHONA-FUENTES, GUILLERMO; ;JORQUERA-AGUILERA, CARLOSBackground Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Test-retest reliability of Latin American Group for Maturity (GDLAM) protocol in older women(PUBLIC LIBRARY SCIENCE, 2024-04-19); ;JOFRÉ-SALDÍA, EMILIO ;ARRIAGADA MOLINA, JIMENA; PARADA TOLEDO, MARÍA PAZFunctional autonomy (FA) is a critical factor in determining the quality of life of older adults (OA), especially in the case of older women (OW), as they face a decline in FA in their later years of life. FA should be assessed early, using valid, reliable, and low-cost tests. This study evaluated the test-retest reliability of GDLAM and GDLAM autonomy index (GI) in OW. Thirty-nine OW (71.2 +/- 6.50 years) participated in the study. A repeated measures design was used to compare the interday test-retest reliability of the five GDLAM tests (seconds) and the GI (points). The five tests represent activities of daily living, such as dressing or wandering around the house, while the GI provides a weighting of the results of the five tests. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. The outcome of the five tests, represented by the GI, showed high interday test-retest reliability (CV = 6.00% and ICC = 0.91). The results of this study demonstrate that the five tests of the GDLAM protocol and the GI have high interday test-retest reliability and good interday reproducibility. From a practical point of view, the GDLAM protocol allows the assessment of FA of community-dwelling OW, providing background for early diagnosis and, with it, the possibility of developing an individualized physical exercise prescription. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Latin American Group for Maturity (GDLAM) protocol: a reliable method to assess the functional autonomy of community-dwelling older men(PEERJ INC, 2026-05-29); ;GALDAMES MALIQUEO, SERGIO ;VALDERRAMA MUÑOZ, MARCELA; Background. Functional autonomy (FA) in older adults can be assessed using the Latin American Group for Maturity Protocol (GDLAM). However, the nter-day reliability of the GDLAM protocol and its General Index of Functional Autonomy (GI) has not been determined in community-dwelling older men (OM). Objective. To determine the inter-day reliability of the GDLAM protocol and the GI in OM, considering the effect of age on these parameters. Materials and methods. Fifty OM participated, divided into two age groups (All: 73.9 +/- 6.9 years; G1 < 75 years: n = 30, 69.2 +/- 3.6 years; G2 >= 75 years: n = 20, 81.0 +/- 3.9 years). A repeated measures design was used to analyze the inter-day reliability of the five functional tests of the GDLAM protocol (in seconds) and the GI (in points). The statistical analysis included the intraclass correlation coefficient (ICC) and the coefficient of variation (CV). Reliability was considered acceptable when CV <= 10% and ICC >= 0.80, and high when CV <= 5% and ICC >= 0.90. Results. The overall analysis and analysis by age group showed high inter-day reliability (All: CV = 4.38%, ICC = 0.91; G1: CV = 3.35%, ICC = 0.93; G2: CV = 4.33%, ICC = 0.92). Conclusion. The GDLAM protocol and GI show high inter-day reliability and reproducibility, supporting their use to assess FA in community-dwelling older adults. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Development of a Percentile-Based Rating Scale for the GDLAM Protocol to Assess Functional Autonomy in Older Chilean Women(MDPI, 2026-04-20); ;JOFRÉ-SALDÍA, EMILIO ;GALDAMES MALIQUEO, SERGIO ;BARAHONA-FUENTES, GUILLERMOThe Latin American Development Group for Maturity (GDLAM) protocol has been widely used to assess functional autonomy (FA) in community-dwelling older adults. However, to date, no percentile-based rating scale has been established for older Chilean women living in the community. The aim was to create a percentile-based rating scale for the GDLAM protocol in community-dwelling older Chilean women. 347 older women volunteered for this study. The sample was divided into five groups by age ranges (G1: 60.0-64.9 years, G2: 65.0-69.9 years, G3: 70.0-74.9 years, G4: 75.0-79.9 years, and G5: >= 80.0 years). The research had an observational, cross-sectional design with a descriptive strategy. The GDLAM protocol included (a) Putting on and taking off a T-shirt (PTS), (b) Standing up from the sitting position (SSP), (c) Standing up from the prone position (SPP), (d) Walking 10 m (W10 m), and (e) Sit-ting and getting up from the chair and moving around the house (SCMA), all assessed in seconds (s), while the General Index of Autonomy (GI) was calculated in points (p). The percentile-based classification was developed with the following thresholds: percentile <= 0.15: "Very Good," percentile 0.16-0.49: "Good," percentile 0.50-084: "Regular," and percentile >= 0.85: "Poor." After creating the percentile-based ranking scale for the five age ranges, it was observed that the older the age, the lower the FA, as represented by the five tests and the GI. The percentile-based ranking scale presented in this research will enable us to accurately assess and interpret the FA of older and community-dwelling women in Chile. However, the study is limited to women and cannot be generalized to older adults in general.
