Este ítem es privado
LAGOS AGUIRRE, CAROLINA TATIANA
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0003-4061-8035 ↗
Scopus Author ID 26026538900 ↗
ResearcherID (Web of Science) DVL-5834-2022 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
2 resultados
Publicaciones
Mostrando 1 - 2 de 2
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Optimized Physiological Monitoring System for COVID-19 Using VLC-Based 3D Localization and Markov Chain Analysis(IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2025-01-01) ;VIERA RIQUELME, EDUARDO ;ALONSO CANDIA, DIEGO ;SOTO, ISMAEL; PALACIOS JÁTIVA, PABLOThis research presents an optimized physiological monitoring system for COVID-19 patients, integrating Visible Light Communication (VLC)-based three-dimensional localization with Markov Chain Analysis. The proposed system enables real-time tracking of vital physiological indicators while balancing localization accuracy and computational efficiency, making it suitable for real-world healthcare applications. The VLC-based localization system was implemented using three LED beacons and optimized through Particle Swarm Optimization (PSO). The analysis revealed that optimal PSO parameters ( c(1)=1.9 , c(2)=2.1 , and w=0.8 ) significantly improved positioning accuracy, with 700 to 1100 particles providing the best trade-off between precision and computational cost. Additionally, the system successfully measured and calibrated cough frequency, respiratory rate, and oxygen saturation (SpO(2) ) using MEMS sensors. The results showed a cough frequency peak at 0.2 Hz, an average respiratory rate of 1.3 breaths per minute, and precise detection of hypoxia events through infrared and red light absorption. To assess disease progression, a Markov Chain Model was developed, analyzing heart rate, temperature, cough frequency, respiratory rate, and SpO(2) levels. The model identified four distinct patient states, ranging from mild to severe conditions, and provided probabilistic insights into symptom deterioration. A heat map analysis confirmed the reliability of state transition probabilities. The study underscores the critical trade-off between localization accuracy and computational efficiency, emphasizing the importance of careful parameter selection for real-time medical applications. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Assessment of Differences Between the Ports of Rotterdam, Valparaiso and San Antonio Towards Smart Ports, Emphasising Digital Technologies(MDPI, 2025-11-21) ;VALENZUELA-SILVA, LUIS ;MUÑOZ, MIGUEL; ;SEPÚLVEDA-ROJAS, J. P.CARRASCO, RAÚLThe objective is to evaluate the differences between the Chilean ports of Valparaiso and San Antonio and the port of Rotterdam in their journey towards smart ports, focusing on Blockchain (BC) technologies, Artificial Intelligence (AI), big data, Internet of Things (IoT), 5G networks and Digital Twins (DT), according to Port 4.0 and 5.0 models. The methodology is a qualitative assessment based on scores from the analysis of Port 4.0 technology information, including labour relations, environmental care and community integration for Port 5.0. The results confirm Rotterdam as representative of a 'Smart Port' for Ports 4.0 and 5.0, showing gaps with Chilean ports, which are rated as 'incipient implementation' in Port 4.0 and 'in transition' in Port 5.0. These differences are due to factors such as investment, financing, infrastructure, governance, regulation, digital human capital, organisational culture and innovation, and the characteristics of the port ecosystem.
