YEOMANS CABRERA, MARÍA MERCEDES

Universidad de Las Américas, Chile

Cargando...
Foto de perfil

Identificación y afiliación académica

Scopus Author ID 16647726200
ResearcherID (Web of Science) AAT-2280-2021

Vínculos académicos

Puesto de trabajo

Resultados de investigación

Publicaciones

Mostrando 1 - 6 de 6
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode
    BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men
    (PEERJ INC, 2026-07-15) ;
    BARAHONA-FUENTES, GUILLERMO
    ;
    ;
    JORQUERA-AGUILERA, CARLOS
    ;
    Background Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Test-retest reliability of Latin American Group for Maturity (GDLAM) protocol in older women
    (PUBLIC LIBRARY SCIENCE, 2024-04-19) ;
    JOFRÉ-SALDÍA, EMILIO
    ;
    ARRIAGADA MOLINA, JIMENA
    ;
    ;
    PARADA TOLEDO, MARÍA PAZ
    Functional autonomy (FA) is a critical factor in determining the quality of life of older adults (OA), especially in the case of older women (OW), as they face a decline in FA in their later years of life. FA should be assessed early, using valid, reliable, and low-cost tests. This study evaluated the test-retest reliability of GDLAM and GDLAM autonomy index (GI) in OW. Thirty-nine OW (71.2 +/- 6.50 years) participated in the study. A repeated measures design was used to compare the interday test-retest reliability of the five GDLAM tests (seconds) and the GI (points). The five tests represent activities of daily living, such as dressing or wandering around the house, while the GI provides a weighting of the results of the five tests. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. The outcome of the five tests, represented by the GI, showed high interday test-retest reliability (CV = 6.00% and ICC = 0.91). The results of this study demonstrate that the five tests of the GDLAM protocol and the GI have high interday test-retest reliability and good interday reproducibility. From a practical point of view, the GDLAM protocol allows the assessment of FA of community-dwelling OW, providing background for early diagnosis and, with it, the possibility of developing an individualized physical exercise prescription.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Analysis and stratification of internal and external loads in rowers of different categories, age groups, and sex: a systematic review and meta-analysis
    (UNIVERSIDADE ESTADUAL PAULISTA - UNESP, 2025-04-16) ;
    RIQUELME GUERRA, MIGUEL
    ;
    ; ;
    MARTÍNEZ-GARCÍA, DARÍO
    Background Competitive rowing has also been on the Olympic program since the first Modern Olympic Games. However, there are no reports that normalize physical performance in the different tests. Aim: The purpose of the study was to analyze and present standardized values of physical performance in rowers of different categories, age groups, and sex. Methods: The search was structured under the PRISMA® guidelines for systematic reviews and meta-analysis. The search was performed in Web of Science, Scopus, SPORTDiscus, PubMed, and MedLine with no time limit until September 2023. Variables analyzed were maximal oxygen consumption (VO2max), heart rate, aerobic power, anaerobic power, and critical rowing speeds. Results: Most studies focus on VO2max. The highest VO2max was in the “elite” men category (5.46 LO2·min-1), while the lowest value was in the “novice” women category (2.88 LO2·min-1). The most frequently used test to evaluate VO2max was the 2,000-meter (m) rowing ergometer. Conclusion: The internal load most evaluated in rowers of all categories, age groups, and sex is VO2max. In most cases, VO2max is evaluated through the 2,000 m rowing ergometer test. However, this test has low reliability in lower-level athletes. In the latter case, exploring tests with a shorter duration (6-min on the rowing ergometer) is suggested.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Latin American Group for Maturity (GDLAM) protocol: a reliable method to assess the functional autonomy of community-dwelling older men
    (PEERJ INC, 2026-05-29) ;
    GALDAMES MALIQUEO, SERGIO
    ;
    VALDERRAMA MUÑOZ, MARCELA
    ;
    ;
    Background. Functional autonomy (FA) in older adults can be assessed using the Latin American Group for Maturity Protocol (GDLAM). However, the nter-day reliability of the GDLAM protocol and its General Index of Functional Autonomy (GI) has not been determined in community-dwelling older men (OM). Objective. To determine the inter-day reliability of the GDLAM protocol and the GI in OM, considering the effect of age on these parameters. Materials and methods. Fifty OM participated, divided into two age groups (All: 73.9 +/- 6.9 years; G1 < 75 years: n = 30, 69.2 +/- 3.6 years; G2 >= 75 years: n = 20, 81.0 +/- 3.9 years). A repeated measures design was used to analyze the inter-day reliability of the five functional tests of the GDLAM protocol (in seconds) and the GI (in points). The statistical analysis included the intraclass correlation coefficient (ICC) and the coefficient of variation (CV). Reliability was considered acceptable when CV <= 10% and ICC >= 0.80, and high when CV <= 5% and ICC >= 0.90. Results. The overall analysis and analysis by age group showed high inter-day reliability (All: CV = 4.38%, ICC = 0.91; G1: CV = 3.35%, ICC = 0.93; G2: CV = 4.33%, ICC = 0.92). Conclusion. The GDLAM protocol and GI show high inter-day reliability and reproducibility, supporting their use to assess FA in community-dwelling older adults.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Environmental pollution and health in Chilean older adults: Impact on quality of life and functional autonomy
    (WILEY, 2024-02-20) ;
    JOFRÉ‐SALDÍA, EMILIO
    ;
    ; ;
    BRAVO, MAXIMILIANO
    Background and Aims: Due to increased urbanization and industry, environmental pollution is a serious public health concern. Globally, the quality of life is particularly lowered by exposure to high amounts of particulate matter (PM). Chile has five industrial zones with high pollution levels, called "sacrifice zones." However, the effect of polluted air on the quality of life and functional autonomy (FA) of older people living in industrial zones with high pollution levels is unknown. Therefore, this study aimed to determine the quality of life and FA differences between Chilean older women (OW) living in areas with lower and higher PM levels. Materials and Methods: Seventy-two OW volunteered for this study. The sample was divided into Zone 1 (PM2.5 <= 15 mu g/m(3), n = 36) and Zone 2 (PM2.5 > 15 mu g/m(3), n = 36). The variables were quality of life-assessed through the SF-36v2.0 questionnaire, and FA-assessed through the GDLAM protocols. Differences between zones were tested by Student's t-test and Mann-Whitney test, both for independent samples (p < 0.05). Results: All eight dimensions of quality of life were lower in Zone 2, of which the role emotional (RE) showed significant differences between zones (p < 0.05). Performance on the GDLAM protocols and the FA index were lower in Zone 2 (p > 0.05). Conclusion: OW in Zone 2 showed lower quality of life and FA. PM could affect the older population's physical and mental health and, therefore, the quality of life.