YEOMANS CABRERA, MARÍA MERCEDES

Universidad de Las Américas, Chile

Cargando...
Foto de perfil

Identificación y afiliación académica

Scopus Author ID 16647726200
ResearcherID (Web of Science) AAT-2280-2021

Vínculos académicos

Puesto de trabajo

Resultados de investigación

Publicaciones

Mostrando 1 - 2 de 2
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Association between muscle quality index and time to stand up from the prone position in community-dwelling older adults
    (PUBLIC LIBRARY OF SCIENCE, 2026-10-05) ;
    JOFRÉ-SALDÍA, EMILIO
    ;
    BARAHONA-FUENTES, GUILLERMO
    ;
    GALDAMES MALIQUEO, SERGIO
    ;
    BRAVO YAPUR, MAXIMILIANO
    Both muscle strength and muscle quality are essential factors for preserving autonomy and functionality in older adults (OA). However, the relationship between muscle quality index (MQI) and the time to stand up from the prone position (SPP) in this population is unknown. The primary purpose of this study was to determine the relationship between MQI and SPP completion time in community-dwelling OA capable of performing the test, considering age, sex, stature, and fat mass percentage. This cross-sectional study included 376 OA (70.47 ± 6.95 years; 234 women and 142 men). Functional Autonomy (FA) was assessed using the GDLAM protocol, and MQI was calculated as manual grip strength divided by body mass index (N/BMI). Pearson's test was used to correlate parametric data, while Spearman's was used for non-parametric data. For both the dominant (D) and non-dominant (N-D) limbs, the analysis showed a high correlation between MQI and time in the SPP test (D: r = −0.55, 95% CI −0.62 to −0.48, p < 0.0001; N-D: r = −0.57, 95% CI −0.64 to −0.50, p < 0.0001). This association remained significant in all four regression models after adjustment (all p < 0.001), with models based on body mass showing greater explanatory power than those based on body mass index (adjusted R² 0.351–0.366 vs. 0.343–0.360). These results indicate that higher MQI is associated with shorter SPP completion time in community-dwelling OA. Therefore, the SPP test shows potential as a practical, field-based indicator associated with FA in this population.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men
    (PEERJ INC, 2026-07-15) ;
    BARAHONA-FUENTES, GUILLERMO
    ;
    ;
    JORQUERA-AGUILERA, CARLOS
    ;
    Background Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals.