TORRES BANDUC, MAXIMILIANO ANDRÉS
Universidad de Las Américas, Chile
Cargando...
Identificación y afiliación académica
Afiliación académica
ORCID 0000-0002-0047-3399 ↗
Scopus Author ID 57216711350 ↗
ResearcherID (Web of Science) DYA-0314-2022 ↗
Vínculos académicos
Puesto de trabajo
Resultados de investigación
4 resultados
Publicaciones
Mostrando 1 - 4 de 4
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode(SAGE PUBLICATIONS INC, 2024-04-27); ; ; BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men(PEERJ INC, 2026-07-15); ;BARAHONA-FUENTES, GUILLERMO; ;JORQUERA-AGUILERA, CARLOSBackground Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effects of a Low Dose of Orally Administered Creatine Monohydrate on Post-Fatigue Muscle Power in Young Soccer Players(MDPI, 2024-05); ;JOFRÉ-SALDÍA, EMILIO; ;GALDAMES MALIQUEO, SERGIOThe use of creatine monohydrate (Cr) in professional soccer is widely documented. However, the effect of low doses of Cr on the physical performance of young soccer players is unknown. This study determined the effect of a low dose of orally administered Cr on muscle power after acute intra-session fatigue in young soccer players. Twenty-eight young soccer players (mean age = 17.1 +/- 0.9 years) were randomly assigned to either a Cr (n = 14, 0.3 g.kg(-1).day(-1) for 14 days) or placebo group (n = 14), using a two-group matched, double-blind, placebo-controlled design. Before and after supplementation, participants performed 21 repetitions of 30 m (fatigue induction), and then, to measure muscle power, they performed four repetitions in half back squat (HBS) at 65% of 1RM. Statistical analysis included a two-factor ANOVA (p < 0.05). Bar velocity at HBS, time: p = 0.0006, eta(2)(p) = 0.22; group: p = 0.0431, eta(2)(p) = 0.12, time x group p = 0.0744, eta(2)(p) = 0.02. Power at HBS, time: p = 0.0006, eta(2)(p) = 0.12; group: p = 0.16, eta(2)(p) = 0.06, time x group: p = 0.17, eta(2)(p) = 0.009. At the end of the study, it was found that, after the induction of acute intra-session fatigue, a low dose of Cr administered orally increases muscle power in young soccer players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Age-dependent Knee Joint Isokinetic Profile in Professional Male Soccer Players(AUSTRALIAN INTERNATIONAL ACADEMIC CENTRE PTY LTD, 2022-10-31); ;JEREZ-MAYORGA, DANIEL; ;BISHOP, CHRISRAMIREZ-CAMPILLO, RODRIGOBackground: The knee-joint isokinetic profile (KJIP) injury risk factor may be modulated by chronological age, however, comparative data for elite male soccer players aged 25 years and older is lacking. Objective: To describe and compare the knee-joint isokinetic profile (KJIP) according to the chronological age of professional male soccer players. Method: In a cross-sectional study design, sixty-three soccer athletes from the first Chilean soccer division (A-series) were divided into younger and older groups (age ≤ 25 years; n = 35 and age > 25 years; n = 28, respectively). In both groups the IPKJ was assessed at 60°.s-1 in concentric mode. Results: The older group had lower extensor peak torque (p < .05). The younger group showed correlations between flexors peak torque and extensors mean power (p < .001). In the older group, flexors peak torque and flexors mean power were correlated. The flexors peak torque, total work, and mean power symmetric index (SI) exhibited values > 10 % for both groups. The extensors SI showed values > 10 % for mean power, although only in the older group. Conclusion: Several differences in the KJIP were noted between professional male soccer players aged ≤ 25 years and > 25 years. Current results offer injury prevention insights, discussed in the current manuscript.
