Ciencia Abierta UDLA
URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336
Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.
Examinar
12 resultados
Resultados de la búsqueda
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men(PEERJ INC, 2026-07-15); ;BARAHONA-FUENTES, GUILLERMO; ;JORQUERA-AGUILERA, CARLOSBackground Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Combined Impact of Creatine, Caffeine, and Variable Resistance on Repeated Sprint Ability in Young Soccer PlayersThere is evidence that both intra-serial variable resistance (I-sVR), as pre-activation within the post-activation performance enhancement cycle (PAPE), and creatine and caffeine supplementation increase athletic performance in isolation. However, the effect of the three conditioning factors on 30 m repeated sprint ability (RSA) performance in young soccer players is unknown. This study determined the summative and isolation effect of ergogenic aids and pre-activation in half-back squats (HBSs) with I-sVR on performance in an RSA test in young soccer players. Twenty-eight young soccer players were randomly assigned to either EG(1) (n = 7, creatine + caffeine + I-sVR), EG(2) (n = 7, creatine + placebo(2) + I-sVR), EG(3) (n = 7, placebo(1) + caffeine + I-sVR), or EG(4) (n = 7, placebo(1) + placebo(2) + I-sVR), using a factorial, four-group-matched, double-blind, placebo-controlled design. Creatine supplementation included 0.3 g/kg/day for 14 days, caffeine supplementation included 0.3 mg/kg per day, and pre-activation in HBS with I-sVR (1 x 5 at 30% 1RM [1.0-1.1 m/s] + 1 x 4 at 60% 1RM [0.6-0.7 m/s]). The RSA test and HBS outcomes were evaluated. Three-way ANOVA showed non-significant differences for the RSA test and HBS outcomes (p > 0.05). At the end of this study, it was found that the three ergogenic aids, together, do not generate a summative effect on the physical performance of young soccer players. However, it is important to analyze individual responses to these specific protocols. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Interference Effects of Different Resistance-Training Protocols on Rowing Ergometer Performance: A Study on Semiprofessional Rowers(HUMAN KINETICS PUBL INC, 2023-11) ;JANICIJEVIC, DANICA; ;BAENA-RAYA, ANDRÉSGARCÍA-RAMOS, AMADORPurpose: To evaluate the interference effects of various resistance-training (RT) protocols on rowing ergometer performance. Methods: Fourteen semiprofessional male rowers randomly completed 5 protocols in separate sessions: (1) control-no RT session was performed, (2) upper-body high-fatigue-4 sets to failure during the bench pull exercise, (3) upper-body lowfatigue-4 sets of 6 repetitions during the bench pull exercise, (4) lower-body high-fatigue-4 sets to failure during the leg-press exercise, and (5) lower-body low-fatigue-4 sets of 6 repetitions during the leg-press exercise. All sets were performed against the 12-repetition-maximumload with 2 minutes of interset rest. Following the completion of the protocols, subjects performed an all-out 1000-m rowing ergometer test. Results: Compared with the control condition, rowing ergometer performance was not significantly affected after the low-fatigue RT protocols (upper body: P >=.487; Delta= 0.0%-0.2%; lower body: P >=.200; Delta= -0.2%-0.5%), while it significantly declined following high-fatigue RT protocols (upper body: P <=.001; Delta = 1.0%2.0%; lower body: P <=.002; Delta= 2.1%-2.5%). The average heart rate was significantly lower for the control condition compared with all RT protocols (P <=.043; Delta= 1.0%-1.5%). Conclusions: To minimize interference on rowing performance, coaches should prioritize the level of effort in RT protocols over specific exercises, specifically avoiding high-fatigue protocols that lead to failure before rowing practice. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Inter-repetition Rest Impact on Percentage of Repetition Completed at Certain Velocity Loss(GEORG THIEME VERLAG KG, 2024-02) ;MARTÍNEZ-RUBIO, CARLOS; ;BAENA-RAYA, ANDRÉS ;RODRÍGUEZ-PÉREZ, MANUEL ANTONIOPÉREZ-CASTILLA, ALEJANDROThis study examined the impact of different inter-repetition rest (IRR) configurations (zero seconds [IRR0], three seconds [IRR3], and self-selected less than five seconds [SSIRR]) on estimating the number of repetitions (Nrep) and the percentage of completed repetitions relative to the maximum number of repetitions possible to failure (%rep) after reaching 10%, 20%, and 30% velocity loss thresholds (VLT). Eighteen men completed three sessions, each with a different IRR configuration, separated by 48-72 hours. Single sets of repetitions to momentary muscular failure were performed against 65%, 75%, and 85% of the one-repetition maximum during free-weight back squat and bench press exercises. No significant differences were reported between IRR configurations for the Nrep ( P >= 0.089) and %rep ( P >= 0.061), except for %rep after reaching the 20-30%VLT against 65%1RM and the 10-20%VLT against 75%1RM in the bench press exercise ( P <= 0.048). Additionally, both Nrep and %rep exhibited high interindividual variability (between-subject CV=14-79%) across the different IRR configurations. The individual %rep-%VLT relationships were slightly stronger than the general %rep-%VLT relationships (median R-2 =0.914-0.971 vs. 0.698-0.900). Overall, regardless of the IRR configuration, this novel velocity-based approach does not guarantee the same effort levels across subjects in the free-weight back squat and bench press sets. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators(MDPI, 2025-04-17) ;VASQUEZ-BONILLA, ALDO A. ;YÁÑEZ-SEPÚLVEDA, RODRIGO ;MONSALVES-ÁLVAREZ, MATÍAS ;TUESTA, MARCELODUCLOS-BASTÍAS, DANIELObjectives: This study aimed to evaluate the reliability of muscle oxygen saturation (SmO2) and its correlation with variables from an inertial measurement unit (IMU) sensor placed on the knee at different exercise intensities. Methods: Fourteen university athletes participated in the study. Incremental ergospirometry was performed to exhaustion to calculate V'O(2)max, determine training zones, heart rate, and workload using the IMU, and analyze muscle metabolism by SmO2. Results: The analysis revealed significant differences between moderate-to-high-intensity zones (80-89% vs. 50-69%, Delta = 27% of SmO2; p < 0.001) and high-intensity zones (90-100% vs. 50-79%, Delta = 35% of SmO2; p < 0.001). SmO2 values showed moderate reliability at moderate exercise intensities (e.g., ICC 0.744 at 50%) and high variability at higher intensities, with ICC values around 0.577-0.594, and CV% increasing up to 77.7% at 100% intensity, indicating decreasing consistency as exercise intensity increases. SmO2 significantly decreases with increasing angular velocity (beta = -13.9, p < 0.001), while knee joint load only shows significant correlations with SmO2 in the moderate-to-high-intensity zones (r = 0.569, p = 0.004) and high-intensity zones (r = 0.455, p = 0.012). Conclusions: SmO2 is a key predictor of performance during maximal incremental exercise, particularly in high-intensity zones. Moreover, SmO2 has the potential to serve as a physiological marker of the internal load on the muscles surrounding the knee during exercise. The SmO2 decrease could depend on the angular velocity and impact of the exposed knee during running. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effect of an Intra-Sets Variable Resistance Potentiation Protocol on Throwing Speed in Elite Female Handball Players(MDPI, 2025-03-25); ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID; BARAHONA-FUENTES, GUILLERMOThe peak velocity of an athlete's throws is a determining factor for sports performance. The aim of this study was to analyze the effects of a post-activation performance enhancement (PAPE) protocol with functional electro-mechanical dynamometry (FEMD) on throwing velocity. Thirteen international-level female handball players voluntarily participated in the study. The PAPE protocol considered four sets of eight repetitions controlled by FEMD (four at 30% of 1RM followed by another four at 60% of 1RM). After each series, the athletes' throwing velocity was measured. Significant differences (p < 0.01) were found in the effect size (ES), which measures the strength of the statistical relationship between two variables by group with the repeated measures ANOVA statistic with an effect size omega 2 = 0.028. The effect size analysis identified measurements that are considered null for the baseline-PAPE 1 comparison and small baseline-PAPE 2, baseline-PAPE 3, and baseline-PAPE 4. When resistance is controlled during the run as with an FEMD device, only two sets of eight repetitions (four repetitions at 30% and four repetitions at 60% of 1RM) are required for the improvement of throwing speed in elite handball players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Intra-session reliability of knee flexion-extension muscle strength monitored using a functional electromechanical dynamometer in female soccer players(FRONTIERS MEDIA SA, 2025-02-25) ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID ;CASTILLO, BRYAN ALFARO; MUÑOZ-BUSTOS, GUSTAVOBackground: The aim of the study was to analyze the relative and absolute reliability of intra-session comparisons of three repetitions in a protocol for assessment peak muscle strength in a knee extension and flexion exercise in competitive female soccer players. Methods: The participants in this research are professional level female soccer players. Peak muscle strength was assessed with functional electromechanical dynamometry (FEMD) for the knee muscles with the following movements: knee flexion (FLE) and extension (EXT). Each movement was assessed at a speed of 0.4 ms-1 unilaterally, recording peak muscle strength values in the concentric phase (CON) and an eccentric phase (ECC). Results: Null differences (ES < 0.19) were detected in the measurements of peak muscle strength of the extensors and flexors of the right and left knee in their concentric or eccentric phases. In the intra-set reliability measures, they reported acceptable absolute reliability (CV% < 9.71) and extremely high relative reliability (ICC = 0.92-0.98). Conclusion: In relation to the results of this study, it can be concluded that the FEMD presents a high relative and absolute intra-series reliability for the evaluation of muscle strength in knee extension and flexion in female soccer players. These reported antecedents may facilitate a more specific evaluation of the function of the muscles of the lower limbs. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Test-Retest Reliability of Concentric and Eccentric Muscle Strength in Knee Flexion-Extension Controlled by Functional Electromechanical Dynamometry in female Soccer(MDPI, 2024-10); ;ULLOA-DÍAZ, DAVID ;RODRÍGUEZ-PEREA, ANGELA ;ARAYA-SIERRALTA, SERGIOGUEDE-ROJAS, FRANCISCOIn the field of sports performance, sports medicine, and physical rehabilitation, there is a great interest in the development of protocols and reliable techniques and instruments for the evaluation of strength produced by athletes. In the last ten years, women's football has increased its popularity and participation in numerous countries, which has contributed to players developing more professionally and requiring more specific muscle strength training to improve their performance. The aim of this study was to analyze the absolute and relative test-retest reliabilities of peak muscle strength in knee flexion (FLE) and extension (EXT) controlled using a functional electromechanical dynamometer (FEMD) in a group of seventeen professional female soccer players (age = 18.64 +/- 0.62 years; weight = 54.72 +/- 7.03 kg; height = 1.58 +/- 0.04 m; BMI = 21.62 +/- 2.70 kg/m(2)). Peak muscle strength was measured with knee flexion (FLE) and extension (EXT) movements at a speed of 0.4 ms(-1) unilaterally in a concentric phase (CON) and an eccentric phase (ECC). No significant mean differences were found in the test-retest analysis (p > 0.05; effect size < 0.14), and high reliability was reported for peak muscle strength assessments in both the CON (ICC) = 0.90-0.95) and the ECC (ICC = 0.85-0.97). Furthermore, stable repeatability was presented for extension in the CON (CV = 7.39-9.91%) and ECC (CV = 8.65-13.64). The main findings of this study show that peak muscle strength in knee flexion and extension in CON and ECC is a measure with acceptable absolute reliability and extremely high relative reliability using the FEMD in professional female soccer players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Reliability and Stability of The Gesture of Different Variants of Throwing of Handball(UNIV NAC, ESCUELA CIENCIAS DEPORTE, 2022-06-21); ;ALFARO CASTILLO, BRYAN SEBASTIÁN ;MARTÍNEZ GARCÍA, DARÍO ;CUEVAS ABURTO, JESUALDOULLOA DÍAZ, DAVID LEONARDOThis study aims to analyze the reliability of the test of 8 throws of 3 different variants of handball throws in university students. The participants were 33 males, 20 +/- 1.9 years; weight 72.39 +/- 8.9 kg; height 176.75 +/- 6.07 cm; BMI 23.14 +/- 2.3. They were evaluated in 2 sessions separated from each other by a period of one week. The participants executed throws until 8 measurements were recorded in each of the tests, unspecific throws, in support and in the race with 3 steps; the launch speed was recorded with a radar behind the goal. The reliability of the average of the test scores of 8 measurements between the first session and the second was measured with a test-retest test. The following results were obtained: in the nonspecific launch, an ICC= (0.86) was obtained between 95% of confidence, one of CV= (7.43%) and one ES = (0.08). For the toss with support, an ICC = (0.94) was obtained at 95% confidence, one of CV = (4.71%) and an ES = (-0.09). For the running throw, an ICC = (0.96) was obtained at 95% confidence, one of CV = (4.00%) and one ES = (0.05). This study has shown that the test of 8 throws and the 3 variants is a reliable and stable performance measure for university-level students without experience in handball; in relation to the throw variables, all 3 were reliable. Only the nonspecific variable was lower compared to the supported and running pitch. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Variable Resistance—An Efficient Method to Generate Muscle Potentiation: A Systematic Review and Meta-Analysis(MDPI, 2023-02-28); ; ; ; CHIROSA-RÍOS, LUIS JAVIERVariable resistance (VR) is a methodology that has shown good results in developing muscular strength and power. However, no updated information relates to the use of VR as an activation to trigger post-activation performance enhancement (PAPE). The primary objective of this systematic review and meta-analysis was to review and qualitatively describe studies published between 2012 and 2022 that used VR to generate PAPE in muscle power-dominant sports. The secondary objective was to calculate the effect size of the different power outcomes reported in the selected studies. The search was designed following the PRISMA® guidelines for systematic reviews and meta-analyses and performed in the Web of Science (WOS), Scopus, SPORTDiscus, PubMed, and MEDLINE between 2012 and 2022. The methodological quality and risk of bias were evaluated with the Cochrane Collaboration tool. The main variables were the throwing speed, time in sprint tests, and jump height. The analysis was conducted with a pooled standardized mean difference (SMD) through a Hedges’ g test (95% CI). Twenty-two studies were included in the systematic review and ten in the meta-analysis, revealing a trivial effect for throwing speed (SMD = 0.06; CI = 95%: −0.23–0.35; p = 0.69), a small effect for the time in sprint tests (SMD = −0.37; CI = 95%: −0.72–−0.02; p = 0.04), and a moderate effect for jump height (SMD = 0.55; CI = 95%: 0.29–0.81; p ˂ 0.0001). All forms of VR used for neuromuscular activation effectively triggered PAPE. Specifically, the results showed that activation with VR generates performance increases in time, in sprint tests and jump height, and a trivial effect in throwing tests (speed and distance).
