Ciencia Abierta UDLA

URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336

Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.

Examinar

Resultados de la búsqueda

Mostrando 1 - 10 de 37
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Free® linear position transducer in the propulsive phase of bench press in men
    (PEERJ INC, 2026-07-15) ;
    BARAHONA-FUENTES, GUILLERMO
    ;
    ;
    JORQUERA-AGUILERA, CARLOS
    ;
    Background Velocity-based training has emerged as a leading approach for quantifying training loads. Therefore, valid and reliable devices must be used to evaluate both movement velocity and power. Objective This study determined the validity and reliability of the Valkyria Trainer Free (R) linear position transducer (VTF (R) LPT) during the propulsive phase of the bench press in physically healthy individuals. Materials and Methods Nineteen physically healthy men participated in the study (22.7 +/- 2.1 years). A repeated-measures design was used to compare the inter-day test-retest reliability of velocity and power, while validity was determined by comparing the VTF (R) LPT with the Chrono-Jump (R) LPT. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) for slow velocity zone: 0.08-0.49 m & centerdot;s(-1), power zone: 0.50-0.99 m & centerdot;s(-1), and fast velocity zone: 1.00-1.56 m & centerdot;s(-1). A CV <= 10% and an ICC >= 0.80 were considered acceptable reliability, whereas a CV <= 5% and an ICC >= 0.90 were considered high reliability. Results For vertical velocity, the "power zone" and "fast velocity zone" showed a high threshold for CV (<= 5%), while the "slow velocity zone" showed an acceptable threshold with a CV of 7.94. For power, the "slow velocity zone" showed an acceptable threshold for CV (<= 10%), while the "fast velocity zone" and "power zone" showed a CV equivalent to 10.8 and 4.8%, respectively. Conclusion The study's results demonstrated that VTF (R) LPT is valid and reliable for assessing velocity and power in physically healthy individuals.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Exploring the interplay between body mass index and passive muscle properties in relation to grip strength and jump performance in female university students
    (PEERJ INC, 2024-11-13)
    PÉREZ, MIGUEL ÁNGEL
    ;
    URREJOLA-CONTRERAS, GABRIELA
    ;
    ALVAREZ, BRIAN
    ;
    STEILEN, CAMILA
    ;
    LATORRE, ANTONIETA
    Background: Women typically have a higher body fat content than men. Fat accumulation is associated with muscle weakness and alterations in mechanical properties. This study aims to determine the relationship between BMI and weight status with the mechanical properties of muscle and tendon. It was hypothesized that the stiffness and tone of the forearm muscle and Achilles tendon would be correlated with weight status and BMI. Methods: A cross-sectional study was conducted with 136 female university students. Grip strength was assessed using a dynamometer, body composition was analyzed through bioimpedance, and countermovement jump performance was evaluated with a force platform. Stiffness and tone were measured using the MyotonPro device. ANOVA was used to compare grip strength and countermovement jump performance according to body composition. The Pearson correlation coefficient was used to examine bivariate associations. Results: Relative grip strength decreased with an increase in fat content, while forearm muscle stiffness and tone decreased with rising weight status and BMI. Stiffness of the Achilles tendon increased with an increase in fat content and showed a significant positive correlation with BMI. Multiple regression analysis revealed a weak correlation between BMI, body composition, and stiffness of the forearm muscles. Conclusion: The results of this study support the notion that the stiffness of the forearm muscles and Achilles tendon is correlated with BMI in young adult women. Furthermore, an increase in body fat percentage is linked to a decrease in mechanical properties and poorer muscle function.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Impact of Starting Knee Flexion Angle on Muscle Activity and Performance during Plyometrics without Jumping
    (MDPI, 2024-01) ;
    CHIROSA-RÍOS, IGNACIO
    ;
    CHIROSA-RÍOS, LUIS
    ;
    JEREZ-MAYORGA, DANIEL
    Most of the existing research has focused on jump plyometrics, where landing reaction forces must be dissipated among lower limb articulations. In contrast, the investigation of resisted plyometrics without jumping, devoid of such landing forces, remains relatively limited. This study aimed to (i) investigate the impact of resisted plyometrics without jumping at two knee flexion angles (60 and 90 degrees) on vastus muscle activity relative to limb dominance and (ii) assess strength, power, and work during the concentric-eccentric phases of these exercises. Thirty-one healthy participants underwent quantification of lower limb muscle amplitude, strength, power, and work during resisted plyometrics without jumping from both 60 degrees and 90 degrees knee flexion positions. After anthropometric evaluations, participants used a dynamometer with a load equal to 80% of body weight while wireless surface electromyography electrodes recorded data. Statistical analyses utilized paired t-tests or nonparametric equivalents and set significance at p <= 0.05. Results showed significantly higher muscle activity in the vastus medialis (VM) (dominant: 47.4%, p = 0.0008, rs = 0.90; nondominant: 54.8%, p = 0.047, rs = 0.88) and vastus lateralis (VL) (dominant: 46.9%, p = 0.0004, rs = 0.86; nondominant: 48.1%, p = 0.021, rs = 0.67) muscles when exercises started at 90 degrees knee flexion, regardless of limb dominance. Substantial intermuscle differences occurred at both 60 degrees (50.4%, p = 0.003, rs = 0.56) and 90 degrees (54.8%, p = 0.005, rs = 0.62) knee flexion, favoring VM in the nondominant leg. Concentric and eccentric strength, power, and work metrics significantly increased when initiating exercises from a 90 degrees position. In conclusion, commencing resisted plyometrics without jumping at a 90 degrees knee flexion position increases VM and VL muscle activity, regardless of limb dominance. Furthermore, it enhances strength, power, and work, emphasizing the importance of knee flexion position customization for optimizing muscle engagement and functional performance.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study
    (MDPI, 2026-07-02)
    FUENTES-BARRÍA, HÉCTOR
    ;
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Inter-Session Reliability of an Isometric Muscle Strength Protocol in Older Adults
    (MDPI, 2026-01-09)
    ANDRADES-RAMÍREZ, OSCAR
    ;
    CEBALLOS-SEPULVEDA, DOMINGO
    ;
    FUENTEALBA-MARTÍNEZ, BENJAMÍN
    ;
    VENEGAS-COFRÉ, BENJAMÍN
    ;
    VALENZUELA-ZIEBALLE, VÍCTOR
    Background: The objective of this study was to analyze the absolute and relative reliability intersession for a maximal isometric muscle strength protocol in the bilateral seated bench press (BSBP), bilateral seated row (BSR), unilateral seated knee right extension (USKER) and unilateral seated knee left extension (USKEL) in a population of older adults. Methods: Eighteen older adults (age = 69.38 +/- 5.06 years; weight = 75.79 +/- 14.18 kg; height = 1.61 +/- 0.08 m; BMI = 28.98 +/- 5.04 kg/m(2). The maximal isometric muscle strength assessment was performed in a seated position. Participants were asked to exert maximum effort during the exercise. The BSBP and BSR assessments were performed bilaterally with shoulders and elbows at 90 degrees, while the USKER and USKEL assessments were performed unilaterally. Three sets of 5 secondswere performed with a 3 minutes rest between measurements until maximum isometric strength was reached in all four measurements. Results: In the inter-session reliability measurements, acceptable absolute reliability was presented for BSR and USKER, and extremely high reliability for the BSBP and USKEL measures. In addition, extremely high relative reliability was reported for all assessments of maximum isometric muscle strength, with no significant differences were observed (p > 0.05) and an ES classified as null (ES < 0.12). Conclusions: The main results of this study show that maximal isometric muscle strength in bilateral seated bench press, bilateral seated row, and unilateral seated right and left knee extension, assessed using the Chronojump Force Sensor Kit, is reliable and reproducible for the elderly population.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Effects of Modified Invasion Games on Motor Competence and Self-Assessed Physical Condition in Elementary School Students in the Physical Education Classroom
    (MDPI, 2024-03-12)
    NEIRA-NAVARRETE, DIEGO
    ;
    PÁEZ-HERRERA, JACQUELINE
    ;
    REYES-AMIGO, TOMÁS
    ;
    YÁÑEZ-SEPÚLVEDA, RODRIGO
    ;
    CORTÉS-ROCO, GUILLERMO
    Modified invasion games promote the development of real and perceived motor competence. Children with higher motor competence are more likely to participate in physical activity practice and to remain in it, both in adolescence and adulthood. (1) Background: The purpose of this study is to determine the effect of modified invasion games on the real motor competence and self-assessment of the physical condition fifth-grade students from a private school in Vina del Mar, Chile. (2) Methods: 40 girls and boys with an average age of 11.47 years (SD = 0.554) participated in this study during a 12-week intervention. The MOBAK 5-6 battery was used to assess actual motor competence, the SEMOK questionnaire was used to determine perceived motor competence, the International Fitness Scale (IFIS) self-assessment questionnaire was used to assess perceived physical fitness, and the weight/size ratio was used to determine BMI. A Friedman's nonparametric ANOVA analysis was applied to determine the effect of the intervention, in addition to an analysis of covariance (ANCOVA) to identify the influence of the covariates on motor competence. (3) Results: No statistically significant differences were established between weight, BMI, and waist circumference. There was a statistically significant difference after the intervention in the actual motor competence of object control (p = 0.005) and perceived motor competence of object control (p <= 0.001) (4) Conclusions: An intervention based on modified invasion games is effective for the improvement of actual and perceived motor competence of object control. It was not possible to identify a positive effect on the self-assessment of muscle strength after the intervention.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Reference Values for Physical Functional Performance Across Childhood, Adolescence, and Early Adulthood in Individuals with Intellectual Disabilities
    (MDPI, 2026-02-14)
    FARÍAS-VALENZUELA, CLAUDIO
    ;
    SUAZO-ROMERO, DAVID
    ;
    HENRÍQUEZ, MATÍAS
    ;
    JOFRÉ-SALDÍA, EMILIO
    ;
    FERRERO-HERNÁNDEZ, PALOMA
    Individuals with Intellectual Disabilities (ID) often exhibit reduced physical fitness, leading to early declines in the ability to perform daily activities. This study aimed to characterize and establish reference values for physical functional performance by sex and age group in school-aged children with ID. A total of 321 participants (ages 5-26 years) from special education schools were assessed. Physical functional performance was measured using the 4 & times; 10 m shuttle run (4 & times; 10 m), Timed Up and Go (TUG), Five-Repetition Sit-to-Stand Test (5R-STS), and Countermovement Jump (CMJ). Two-way ANOVA, Kruskal-Wallis tests, and percentile values (5th-95th) were calculated by sex and age group. Males consistently demonstrated higher performance than females. Cross-sectional comparisons showed higher 4 & times; 10 m, TUG, and 5R-STS performance during adolescence in both sexes, while CMJ performance was higher in males during early adulthood. Adolescents outperformed children in 4 & times; 10 m, TUG, and CMJ tests (p < 0.05). Females exhibited lower 4 & times; 10 m and CMJ performance in early adulthood compared with adolescence (p < 0.05), whereas males showed no significant differences across these stages. Physical functional performance in individuals with ID varied according to sex and age, with males generally demonstrating better performance. Adolescence is associated with higher performance, while females experience reductions in lower-limb power in early adulthood. These findings highlight sex- and age-related differences and support the need for targeted monitoring and intervention strategies in this population.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Asymmetry in Hamstring Strength Among Soccer Players During the Swing Eccentric Hamstring Exercise: Implications Across Playing Positions
    (MDPI, 2026-02-12)
    RIEGO-RUIZ, ANTONIO
    ;
    RUIZ-GARCES, CARLOS
    ;
    CHIROSA-RÍOS, IGNACIO
    ;
    CONTRERAS-DIAZ, GUIDO
    ;
    DELGADO-FLOODY, PEDRO
    Background: In soccer, the repeated execution of unilateral actions may lead to uneven limb development, promoting the occurrence of asymmetries. However, there is no consensus on the impact of these asymmetries on sports performance or the influence of playing position on their magnitude. Methods: A cross-sectional study was conducted with 33 male federated soccer players (age: 18.42 +/- 4.24 years; body mass: 70.23 +/- 8.74 kg; height: 1.76 +/- 0.07 m; body mass index: 22.6 +/- 2.7 kg/m2). Hamstring strength asymmetry between the dominant and non-dominant limbs was assessed using functional electromechanical dynamometer (FEMD) at eccentric velocities of 0.4, 0.8, and 1.2 m/s. Physical performance was evaluated through a 30 m sprint and countermovement jump (CMJ). Differences according to playing position were also analyzed. Results: Significant between-limb differences were found in strength, power, and impulse, with effect sizes increasing as testing velocity rose. No significant differences in asymmetry levels were observed across playing positions, and no correlations were found between hamstring asymmetry and physical performance outcomes. Conclusions: Although functional lower-limb asymmetries were identified in soccer players, these asymmetries did not directly influence performance nor vary across playing positions. The findings suggest that certain asymmetries may represent normal functional adaptations in soccer rather than pathological structural imbalances.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Reliability of the PREFIT fitness-test battery in Chilean preschoolers
    (FRONTIERS MEDIA SA, 2026-01-12)
    SOTO-SÁNCHEZ, JOHANA
    ;
    LEYTON-DINAMARCA, BARBARA
    ;
    KAIN, JULIANA
    ;
    FERNÁNDEZ-VALERO, PAZ
    ;
    Introduction This study explores the test-retest reliability of the FITness in PREschoolers (PREFIT) battery, including cardiorespiratory fitness [20 m shuttle run test (SRT)], upper-body muscle strength (handgrip strength), lower-body explosive strength (standing long jump), speed (4 x 10 m shuttle run), and static balance (one-leg stance), in Chilean preschoolers considering weight status, sex, and age.Methods The study included 171 Chilean preschoolers (5.4 +/- 0.7 years). The PREFIT battery was applied using a test-retest design within 7-10 days between evaluations, and weight status was determined using BMI z-scores (ClinicalTrials.gov: NCT04269135). Statistical analyses included test-retest differences, Lin's concordance correlation coefficient, Cohen's effect size (d), standard error of measurement, intraclass correlation coefficient (ICC), and Bland-Altman plots. Analyses were performed using STATA.Results Among the 171 preschoolers (5.4 +/- 0.7 years), test-retest reliability ranged from excellent to moderate for handgrip strength (ICC = 0.8502; 95% CI: 0.81-0.90), 4 x 10 m shuttle run test (ICC = 0.7696, 95% CI: 0.71-0.84), and PREFIT 20 m SRT (ICC = 0.6656; 95% CI: 0.58-0.74), but was poor for the one-leg stance test (ICC = 0.46; 95% CI: 0.36-0.63). SEM and MDC95 values indicated that changes of 0.85 kg, MDC = 9,502.35 kg (handgrip strength), >= 0.89 s (4 x 10 m shuttle run test), >= 5.33 laps (20 m shuttle run test), and >= 12.43 cm (standing long jump) exceeded measurement error. Reliability was similar across sex, age, and weight-status groups. Bland-Altman analyses showed proportional bias and heteroscedasticity for the 20 m shuttle run test and one-leg stance. At the same time, the remaining tests demonstrated consistent measurement error throughout the performance spectrum.Conclusion The PREFIT battery is appropriate for field application among Chilean preschool children, except for the one-leg stance test, which demonstrated inadequate reliability and proportional bias. Reporting MDC95 enables the interpretation of significant change within educational and intervention contexts.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validity and reliability of the Valkyria Trainer Balance® portable force platform in itsisometric mode
    BACKGROUND: Isometric maximal voluntary force (IMVF) is essential for individuals' health and physical performance. Therefore, there is a need for valid and reliable devices to assess IMVF. OBJECTIVE: To determine the validity and reliability of the Valkyria Trainer Balance (R) portable force platform in its isometric mode. METHODS: Fifty-eight physically healthy individuals (30 men and 28 women) participated in the study. A repeated measures design was used to compare the inter-day test-retest reliability of peak force. The validity of the Valkyria Trainer Balance (R) R force platform was determined by comparing the peak force with the ArtOficio (R) force platform. The analysis consisted of the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). A CV <= 10% and ICC >= 0.80 were considered acceptable reliability, while a <= 5% and ICC >= 0.90 were regarded as high reliability. RESULTS: CV the peak force showed high test-retest inter-day reliability (CV = 4.3% and ICC = 0.99). When comparing both force platforms, there was a 1.1% difference between the two devices. CONCLUSIONS: The results of this study demonstrate that the Valkyria Trainer Balance (R) R force platform is valid and reliable for assessing IMVF in physically healthy individuals.