Ciencia Abierta UDLA

URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336

Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.

Examinar

Resultados de la búsqueda

Mostrando 1 - 10 de 10
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Impact of Starting Knee Flexion Angle on Muscle Activity and Performance during Plyometrics without Jumping
    (MDPI, 2024-01) ;
    CHIROSA-RÍOS, IGNACIO
    ;
    CHIROSA-RÍOS, LUIS
    ;
    JEREZ-MAYORGA, DANIEL
    Most of the existing research has focused on jump plyometrics, where landing reaction forces must be dissipated among lower limb articulations. In contrast, the investigation of resisted plyometrics without jumping, devoid of such landing forces, remains relatively limited. This study aimed to (i) investigate the impact of resisted plyometrics without jumping at two knee flexion angles (60 and 90 degrees) on vastus muscle activity relative to limb dominance and (ii) assess strength, power, and work during the concentric-eccentric phases of these exercises. Thirty-one healthy participants underwent quantification of lower limb muscle amplitude, strength, power, and work during resisted plyometrics without jumping from both 60 degrees and 90 degrees knee flexion positions. After anthropometric evaluations, participants used a dynamometer with a load equal to 80% of body weight while wireless surface electromyography electrodes recorded data. Statistical analyses utilized paired t-tests or nonparametric equivalents and set significance at p <= 0.05. Results showed significantly higher muscle activity in the vastus medialis (VM) (dominant: 47.4%, p = 0.0008, rs = 0.90; nondominant: 54.8%, p = 0.047, rs = 0.88) and vastus lateralis (VL) (dominant: 46.9%, p = 0.0004, rs = 0.86; nondominant: 48.1%, p = 0.021, rs = 0.67) muscles when exercises started at 90 degrees knee flexion, regardless of limb dominance. Substantial intermuscle differences occurred at both 60 degrees (50.4%, p = 0.003, rs = 0.56) and 90 degrees (54.8%, p = 0.005, rs = 0.62) knee flexion, favoring VM in the nondominant leg. Concentric and eccentric strength, power, and work metrics significantly increased when initiating exercises from a 90 degrees position. In conclusion, commencing resisted plyometrics without jumping at a 90 degrees knee flexion position increases VM and VL muscle activity, regardless of limb dominance. Furthermore, it enhances strength, power, and work, emphasizing the importance of knee flexion position customization for optimizing muscle engagement and functional performance.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study
    (MDPI, 2026-07-02)
    FUENTES-BARRÍA, HÉCTOR
    ;
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Postural Balance and Human Movement: An Integrative Framework for Mechanisms, Assessment, and Functional Implications
    (MDPI, 2026-03-28)
    GUZMÁN-MUÑOZ, EDUARDO
    ;
    MONTALVA-VALENZUELA, FELIPE
    ;
    GARCIA-CARRILLO, EXAL
    ;
    ;
    LÓPEZ-GIL, JOSÉ FRANCISCO
    Postural balance is a foundational component of human motor behavior, yet it remains conceptually ambiguous and methodologically heterogeneous across the clinical, educational, and sport sciences. This narrative review aims to provide an integrative framework that clarifies key concepts (postural control vs. postural balance), synthesizes the main sensorimotor and biomechanical mechanisms underpinning balance, and organizes current assessment approaches and functional implications across populations. Narrative literature synthesis was conducted to integrate evidence covering multisensory integration and sensory reweighting, central neural control (spinal, brainstem, cerebellar, and cortical contributions), neuromuscular and biomechanical strategies (e.g., ankle/hip/stepping), and cognitive influences (e.g., dual-task effects). We further summarize commonly used instrumental outcomes derived from force-platform center-of-pressure metrics and widely adopted clinical and functional balance tests, highlighting their typical applications and limitations across the lifespan including pediatric, general adults, older adults, and athletic populations. This review proposes a closed-loop, systems-based model in which postural balance is conceptualized as an emergent functional outcome arising from distributed postural control processes shaped by task, environmental, and individual constraints. In conclusion, integrating mechanistic understanding with population-specific assessment enhances interpretability and supports more precise, context-sensitive balance evaluation and intervention in both health and performance settings.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Effects of different lower limb strengthening protocols on muscle activity, strength and power in sedentary and physically inactive subjects: a systematic review
    (ARAN EDICIONES, S L, 2024)
    JEREZ MAYORGA, DANIEL
    ;
    ;
    CHIROSA-RÍOS, LUIS
    ;
    CHIROSA-RÍOS, IGNACIO J.
    The purpose of this systematic review was: a) to determine the quality of evidence from studies assessing the effects of different lower limb strengthening protocols on muscle activity, strength, and power in sedentary and/or physically inactive subjects; and b) to determine the effectiveness of lower extremity strengthening protocols on muscle activity, strength, and power in sedentary and/or physically inactive subjects. Preferred Reporting Items for Systematic Review and Meta -Analyses (PRISMA) statements were followed using keywords associated with strength training, lower limb, sedentary, and physical inactivity. Four databases were used: Medline via PubMed, Web of Science, Scopus and SPORTDiscus. Methodological quality was assessed using the PEDro scale. A total of 164 articles were retrieved, six included in this review. Four studies were classified as fair methodological quality, and two were considered of good methodological quality. Due to the heterogeneity in methodological aspects and the limited number of articles including the variables under study, it was not possible to establish a measure of effectiveness of lower limb strengthening protocols on muscle activity, strength, or power. In conclusion, strength training in the lower limb seems to improve the levels of strength, power, and muscular activity in sedentary subjects. However, due to the limited number of articles, methodological variability, and training methods used, it is necessary to conduct new studies that control these variables.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Minimum effective plyometric training volume in sedentary individuals: Impact on lower limb viscoelastic properties and functional performance in a randomised controlled trial
    (TAYLOR & FRANCIS LTD, 2024-10-01) ;
    CHIROSA-RÍOS, LUIS
    ;
    CHIROSA-RIOS, IGNACIO
    ;
    JEREZ-MAYORGA, DANIEL
    Sedentary lifestyles reduce muscle mass, strength, power, and alter viscoelastic properties. Plyometric jump training (PJT) shows promise in countering these effects, but the optimal training volume for individuals with low athletic performance remains unclear. This study aimed to determine the minimal PJT volume required to improve muscle and tendon viscoelastic properties, strength, and power in sedentary individuals. A double-blind randomised controlled trial included 44 participants divided into three groups: Control Group (CG) (n = 16), Reduced Volume Training Group (RVTG) (n = 16), and Training Group (TG) (n = 12). The four-week PJT programme involved three weekly sessions with gradual volume increments; RVTG performed 50% less volume than TG. Baseline and follow-up assessments included the isokinetic standing up (SU) and sitting down (SD) phases at 15 cm/s and 5 cm/s, and myotonometer measurements. In the SU phase at 15 cm/s, significant differences were found (p = 0.01) with higher values in TG (10.0 +/- 3.3 N/kg) compared to CG and RVTG. At 5 cm/s, differences in SD were observed (p = 0.002). For Achilles tendon properties in RVTG: stiffness (p = 0.04), decrement (p = 0.01), and relaxation (p = 0.02). A PJT volume of 2,414 jumps improved muscle strength, while 1,207 jumps altered tendon properties.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study
    (MDPI, 2025-11-22) ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 +/- 4.97 years; body mass index: 25.79 +/- 3.02 kg/m(2)) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland-Altman analysis and Pearson's correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86-0.91) and moderate-to-good inter-platform reliability (ICC = 0.75-0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75-0.87) and higher variability (CV = 47-57%). Bland-Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R-2 = 0.55-0.77; beta = 0.74-0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study
    (MDPI, 2025-10-27)
    GARRIDO-OSORIO, VÍCTOR
    ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    SANHUEZA-GONZÁLEZ, SEBASTIÁN
    ;
    SANDOVAL-JELVES, CATARÍ
    ;
    AGUILERA-EGUÍA, RAÚL
    Background/Objectives: Low-cost portable load cell dynamometers allow for real-time assessment of muscular strength. This study evaluated the reliability and repeatability of the G-Force load cell system during isometric hip abduction and adduction in young physically active Chilean adults. Methods: In total, 24 participants (19 men, 5 women) performed two maximal voluntary contractions per movement, repeated after a 24 h interval. Measured variables included Peak Force, peak rate of force development (Peak RFD), RFD at 50, 100, and 200 ms (RFD50, RFD100, RFD200), and maximum jerk. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV%) and Bland-Altman plots. Results: Peak Force showed excellent within-day (ICC = 0.94-0.96) and high between-day reliability (ICC = 0.87-0.89; CV = 20-30%). Bland-Altman analysis indicated negligible bias for Peak Force in abduction (-6.54 N; 95% CI -19.55 to 6.47) and adduction (-17.57 N; 95% CI -37.24 to 2.09), confirming the absence of systematic error. Peak RFD, RFD50-200, and maximum Jerk showed moderate repeatability and lower between-day reliability (ICCs = 0.39-0.70; CVs = 34-57%), indicating higher variability in explosive force indices compared with maximal strength. Conclusions: The G-Force load cell reliably measures maximal isometric hip strength, while Peak RFD, RFD50-200, and maximum jerk should be interpreted cautiously. These findings support the device as a practical, low-cost tool for sports and rehabilitation, though future studies should validate dynamic indices in larger and more diverse populations.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Differences in glottic and supraglottic behavior and vocal fold structure in women with odynophonia and asymptomatic women
    (UNIV CASTILLA-LA MANCHA, 2022-07-27)
    FUENTES, CHRISTOPHER
    ;
    ;
    Universidad Mayor
    ;
    Universidad de Las Americas - Chile
    The study of odynophonia has been scarcely addressed by the sciences related to vocal pathology and rehabilitation. The understanding of essential aspects for its therapeutics, such as glottic and supraglottic behavior, is still emerging. The aim of this study was to compare glottic and supraglottic behavior and vocal fold structure in women with odynophonia and asymptomatic women. We worked with 50 women with professional voices; whose average age was 25.78 +/- 3.50 years old. Two groups were formed, G1 (asymptomatic women) and G2 (women with odynophonia). A videolaryngoscope with continuous lighting was used to examine supraglottic behavior and chordal structure, and an electroglottograph was used to analyze vocal fold behavior. In supraglottic behavior, 64% of G2 participants showed a greater severity than G1. The union between anteroposterior shortening and medial compression was the most frequent configuration in G2 and anteroposterior shortening alone was in G1. In 60% and 84% of G2 subjects, prominence of the vocal process and ventriculus spacious was observed along with a thinned vocal cord, respectively. Electroglottography revealed that the closed quotient was 0.50 +/- 0.34 in G1, and 0.41 +/- 0.31 (P < 0.05) in G2. In conclusion, in women with odynophonia, signs of chordal atrophy were observed, while in oscillation compensatory supraglottic compressions and anomalies related to chordal approximation or adduction were observed.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Variable Resistance—An Efficient Method to Generate Muscle Potentiation: A Systematic Review and Meta-Analysis
    Variable resistance (VR) is a methodology that has shown good results in developing muscular strength and power. However, no updated information relates to the use of VR as an activation to trigger post-activation performance enhancement (PAPE). The primary objective of this systematic review and meta-analysis was to review and qualitatively describe studies published between 2012 and 2022 that used VR to generate PAPE in muscle power-dominant sports. The secondary objective was to calculate the effect size of the different power outcomes reported in the selected studies. The search was designed following the PRISMA® guidelines for systematic reviews and meta-analyses and performed in the Web of Science (WOS), Scopus, SPORTDiscus, PubMed, and MEDLINE between 2012 and 2022. The methodological quality and risk of bias were evaluated with the Cochrane Collaboration tool. The main variables were the throwing speed, time in sprint tests, and jump height. The analysis was conducted with a pooled standardized mean difference (SMD) through a Hedges’ g test (95% CI). Twenty-two studies were included in the systematic review and ten in the meta-analysis, revealing a trivial effect for throwing speed (SMD = 0.06; CI = 95%: −0.23–0.35; p = 0.69), a small effect for the time in sprint tests (SMD = −0.37; CI = 95%: −0.72–−0.02; p = 0.04), and a moderate effect for jump height (SMD = 0.55; CI = 95%: 0.29–0.81; p ˂ 0.0001). All forms of VR used for neuromuscular activation effectively triggered PAPE. Specifically, the results showed that activation with VR generates performance increases in time, in sprint tests and jump height, and a trivial effect in throwing tests (speed and distance).
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Dietary carbohydrate-to-protein ratio influences growth performance, hepatic health and dynamic of gut microbiota in atlantic salmon (Salmo salar)
    (KEAI PUBLISHING LTD, 2022-09) ;
    RAMÍREZ, CAROLINA
    ;
    RODRÍGUEZ, HÉCTOR
    ;
    DANTAGNAN, PATRICIO
    ;
    HERNÁNDEZ, ADRIÁN
    Atlantic salmon (Salmo salar) fed a carbohydrate-rich diet exhibit suboptimal growth performance, along with other metabolic disturbances. It is well known that gut microbes play a pivotal role in influencing metabolism of the host, and these microbes can be modified by the diet. The main goal of the present study was to determine the effect of feeding graded levels of digestible carbohydrates to Atlantic salmon on the distal intestine digesta microbiota at 3 sampling times (i.e., weeks 4, 8 and 12), during a 12-week trial. A low carbohydrate-to-high protein diet (LC/HP, 0% wheat starch), a medium carbohydrate-to medium protein diet (MC/MP, 15% wheat starch) or a high carbohydrate-to-low protein diet (HC/LP, 30% wheat starch) was fed to triplicate fish tanks (27 to 28 fish per tank). We performed an in-depth characterization of the distal intestine digesta microbiota. Further, growth parameters, liver histology and the expression of genes involved in hepatic neolipogenesis in fish were measured. Fish fed a HC/LP diet showed greater hepatosomatic and viscerosomatic indexes (P = 0.026 and P = 0.018, respectively), lower final weight (P = 0.005), weight gain (P = 0.003), feed efficiency (P = 0.033) and growth rate (P = 0.003) compared with fish fed the LC/HP diet. Further, feeding salmon a high digestible carbohydrate diet caused greater lipid vacuolization, steatosis index (P = 0.007) and expression of fatty acid synthase (fas) and delta-6 fatty acyl desaturase (d6fad) (P = 0.001 and P = 0.001, respectively) in the liver compared with fish fed the LC/HP diet. Although, the major impact of feeding a carbohydrate-rich diet to Atlantic salmon in beta diversity of distal intestine digesta microbiota was observed at week 4 (HC/LP vs MC/MP and HC/LP vs LC/HP; P = 0.007 and P = 0.008, respectively) and week 8 (HC/LP vs MC/MP; P = 0.04), no differences between experimental groups were detected after 12 weeks of feeding. Finally, at the end of the trial, there was a negative correlation between lactic acid bacteria (LAB) members, including Leuconostoc and Lactobacillus, with hepatic steatosis level, the hepatosomatic and viscerosomatic indexes as well as the expression of fas and d6fad. Weissella showed negative correlation with hepatic steatosis level and the hepatosomatic index. Finally, further research to explore the potential use of LAB as probiotics to improve liver health in carnivorous fish fed fatty liver-induced diet is warranted. (c) 2022 Chinese Association of Animal Science and Veterinary Medicine. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).