Ciencia Abierta UDLA

URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336

Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.

Examinar

Resultados de la búsqueda

Mostrando 1 - 2 de 2
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validation and application of quick polar pesticide (QuPPe) extraction and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to analyze perchlorate in vegetables from Mexico
    (UNIV AUTONOMA NAYARIT, 2024-10-24)
    LEYVA MORALES, JOSÉ BELISARIO
    ;
    ;
    GARCÍA-HERNÁNDEZ, JAQUELINE
    ;
    PALMA, PAULINA
    ;
    BASTIDAS-BASTIDAS, PEDRO DE JESÚS
    El perclorato Perchlorate is considered a contaminant that can cause endocrine disruption in people exposed through various foods, including vegetables. To address the lack of information on this health problem in Mexico, we developed an analytical method to quantify perchlorate in commonly consumed vegetables based on quick polar pesticide (QuPPe) extraction and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). According to SANTE guidelines, the method was validated through selectivity, accuracy, precision, linearity, matrix effect, limit of detection (LOD), and limit of quantification (LOQ). The developed method exhibited a linear range of 0.005-0.100 mg/kg with LOD and LOQ values of 0.001 and 0.003 mg/kg, respectively. Recovery in a fortified tomato matrix was 96.85 +/- 12.90 % with a coefficient of variation (CV) of 11.55 +/- 0.84 %. The method was applied to analyze 31 vegetable samples collected from different regions in Mexico. Perchlorate concentrations ranged from not detected (ND) to 0.016 mg/kg, fresh weight. This method generates robust scientific evidence to implement and strengthen perchlorate monitoring programs for food matrices, supporting efforts to regulate this analyte in Mexico.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Development of an enzyme-linked immunosorbent assay for newborns dried blood spot thyroglobulin
    (BIOSCIENTIFICA LTD, 2024-12-01)
    FUENTES PEÑA, CAMILO
    ;
    ;
    MÉNDEZ, LUIS
    ;
    RIEDEL, CLAUDIA
    ;
    HAUQUIER, BERNARD
    Background Thyroglobulin (Tg) is a biomarker of iodine status. Newborn Tg is a more sensitive marker than neonatal TSH in detecting variations in iodine intake. This study aims to validate an enzyme-linked immunosorbent assay (ELISA) for Tg determination on dried blood spots (DBS) in newborns. This study also sets out to assess the stability of Tg and the influence of newborns' hematocrit on Tg determination. Methods A commercially available ELISA Tg assay was adapted for use on DBS. DBS-Tg in cord blood was measured in 209 newborns delivered from healthy euthyroid pregnant women. Sensitivity, linearity, repeatability, and intermediate fidelity were determined using the appropriate standards and quality control materials. Results The limit of detection of the DBS-Tg assay was 2.4 mu g/L, and the limit of quantification was 5.8 mu g/L. Repeatability and intermediate fidelity were 7.7-8.3% and 11.0-11.2%, respectively. The median cord plasma Tg and DBS-Tg values in newborns were not significantly different, 30.2 (21.3-44.4) mu g/L and 31.6 (19.3-48.7) mu g/L (P = 0.48) with the ELISA, respectively, and 76.5 (40.0-101.5) mu g/L with the Elecsys assay with an R = 0.88. DBS-Tg concentrations decrease with increasing hematocrit values (P < 0.05). DBS-Tg values were stable at a concentration of 25 g/L for 12 months at -20 degrees C and 4 degrees C. Conclusion This DBS-Tg assay demonstrated good analytical performance over a wide range of Tg concentrations, suggesting it is well suited to detecting variations in Tg concentrations. Studies comparing populations with different prevalence of anemia should consider the effect of hematocrit on DBS-Tg determination. The availability of a DBS-Tg assay for newborns makes it possible to integrate iodine status monitoring with newborn screening for inherited metabolic diseases.