Ciencia Abierta UDLA
URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336
Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.
Examinar
6 resultados
Resultados de la búsqueda
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study(MDPI, 2026-07-02) ;FUENTES-BARRÍA, HÉCTOR; ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study(MDPI, 2025-11-22); ;FUENTES-BARRÍA, HÉCTOR ;AGUILERA-EGUÍA, RAÚL ;ROCO-VIDELA, ÁNGELObjectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 +/- 4.97 years; body mass index: 25.79 +/- 3.02 kg/m(2)) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland-Altman analysis and Pearson's correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86-0.91) and moderate-to-good inter-platform reliability (ICC = 0.75-0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75-0.87) and higher variability (CV = 47-57%). Bland-Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R-2 = 0.55-0.77; beta = 0.74-0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Exercise-Induced Molecular Adaptations in Chronic Non-Communicable Diseases-Narrative Review(MDPI, 2025-12-16) ;FUENTES-BARRÍA, HÉCTOR ;AGUILERA-EGUÍA, RAÚL ;ALARCÓN-RIVERA, MIGUEL ;LÓPEZ-SOTO, OLGAARISTIZABAL-HOYOS, JUAN ALBERTOPhysical exercise is a potent non-pharmacological strategy for the prevention and management of chronic non-communicable diseases (NCDs), including type 2 diabetes, cardiovascular diseases, obesity, and certain cancers. Growing evidence demonstrates that the benefits of exercise extend beyond its physiological effects and are largely mediated by coordinated molecular and cellular adaptations. This review synthesizes current knowledge on the key mechanisms through which exercise modulates metabolic health, emphasizing intracellular signaling pathways, epigenetic regulation, and myokine-driven inter-organ communication. Exercise induces acute and chronic activation of pathways such as AMPK, PGC-1 alpha, mTOR, MAPKs, and NF-kappa B, leading to enhanced mitochondrial biogenesis, improved oxidative capacity, refined energy sensing, and reduced inflammation. Additionally, repeated muscle contraction stimulates the release of myokines-including IL-6, irisin, BDNF, FGF21, apelin, and others-that act through endocrine and paracrine routes to regulate glucose and lipid metabolism, insulin secretion, adipose tissue remodeling, neuroplasticity, and systemic inflammatory tone. Epigenetic modifications and exercise-responsive microRNAs further contribute to long-term metabolic reprogramming. Collectively, these molecular adaptations establish exercise as a systemic biological stimulus capable of restoring metabolic homeostasis and counteracting the pathophysiological processes underlying NCDs. Understanding these mechanisms provides a foundation for developing targeted, personalized exercise-based interventions in preventive and therapeutic medicine. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study(MDPI, 2025-10-27) ;GARRIDO-OSORIO, VÍCTOR ;FUENTES-BARRÍA, HÉCTOR ;SANHUEZA-GONZÁLEZ, SEBASTIÁN ;SANDOVAL-JELVES, CATARÍAGUILERA-EGUÍA, RAÚLBackground/Objectives: Low-cost portable load cell dynamometers allow for real-time assessment of muscular strength. This study evaluated the reliability and repeatability of the G-Force load cell system during isometric hip abduction and adduction in young physically active Chilean adults. Methods: In total, 24 participants (19 men, 5 women) performed two maximal voluntary contractions per movement, repeated after a 24 h interval. Measured variables included Peak Force, peak rate of force development (Peak RFD), RFD at 50, 100, and 200 ms (RFD50, RFD100, RFD200), and maximum jerk. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV%) and Bland-Altman plots. Results: Peak Force showed excellent within-day (ICC = 0.94-0.96) and high between-day reliability (ICC = 0.87-0.89; CV = 20-30%). Bland-Altman analysis indicated negligible bias for Peak Force in abduction (-6.54 N; 95% CI -19.55 to 6.47) and adduction (-17.57 N; 95% CI -37.24 to 2.09), confirming the absence of systematic error. Peak RFD, RFD50-200, and maximum Jerk showed moderate repeatability and lower between-day reliability (ICCs = 0.39-0.70; CVs = 34-57%), indicating higher variability in explosive force indices compared with maximal strength. Conclusions: The G-Force load cell reliably measures maximal isometric hip strength, while Peak RFD, RFD50-200, and maximum jerk should be interpreted cautiously. These findings support the device as a practical, low-cost tool for sports and rehabilitation, though future studies should validate dynamic indices in larger and more diverse populations. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Polysomnographic and Electromyographic Evaluation of Sleep Bruxism in Young Colombian Adults: Case-Control Study(MDPI, 2025-09-17) ;LÓPEZ-SOTO, OLGA PATRICIA ;ARISTIZÁBAL-HOYOS, JUAN ALBERTO ;FUENTES-BARRÍA, HÉCTOR ;AGUILERA-EGUÍA, RAÚLGALLÓN-BEDOYA, KAREN SOFIABackground: Sleep bruxism (SB) is increasingly recognized not merely as a movement disorder but as a multifactorial condition in which physiological, behavioral, and contextual factors converge. Objective: To comprehensively characterize SB in young adults, integrating polysomnography (PSG) and surface electromyography (sEMG) to describe sleep architecture, periodic limb movements (PLMs), and masticatory muscle activity; compare these parameters with matched controls; and explore clinical correlations relevant to dental practice and individualized management. Methods: Forty university adults (20 PSG-confirmed SB; 20 controls) underwent PSG assessment of total sleep time, sleep stages, arousals, apnea, oximetry, and PLMs. EMG activity of the masseter and temporalis muscles was recorded in 37 participants (18 SB, 19 controls). Statistical analyses included t-tests, Mann-Whitney U tests, and multivariate logistic regression to identify independent predictors of SB. Results: SB participants exhibited higher bruxism event counts (p <= 0.001; PS = 0.94), increased PLMs (p <= 0.01; PS = 0.75), shorter REM sleep duration (p = 0.04; d = 0.69), and higher bruxism-related arousal indices (p <= 0.001; PS = 83.4). Left masseter activity differed significantly (p = 0.03; d = 0.50), while other muscle measures showed no significant differences. Logistic regression identified age (OR = 0.59, p = 0.02), PLMs (OR = 0.96, p = 0.03), and REM sleep duration (OR = 0.98, p = 0.05) as independent predictors, explaining 58% of the variance. Conclusions: These findings provide a comprehensive profile of SB in young adults. Integrating PSG, sEMG, and oral assessments supports early diagnosis, personalized management, and interdisciplinary collaboration to prevent complications. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, DISCORDANCE BETWEEN ALLELIC AND GENOTYPE FREQUENCIES FOR CD36 rs3211938 BETWEEN MEXICAN MESTIZO SAMPLES: SAMPLE BIAS, GENOTYPING ERROR, OR MICROEVOLUTION?(ARAN EDICIONES, S L, 2022-01) ;FLORES, SERGIO ;ROCO-VIDELA, ÁNGEL; ;Universidad Autonoma de ChileUniversidad Bernardo O'Higgins[No abstract available]
