Ciencia Abierta UDLA
URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336
Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.
Examinar
8 resultados
Resultados de la búsqueda
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effects of artificial photoperiods on antigen-dependent immune responses in rainbow trout (Oncorhynchus mykiss)(ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD, 2023-06) ;GOLDSTEIN, MERARI; ;WONG-BENITO, VALENTINA ;BARRAZA-ROJAS, FELIPETORT, LLUISIn this study, we investigated the effects of the artificial photoperiods that mimic summer (16L:8D; 16 h Light: 8 h Dark) and winter (8L:16D) solstices, equinoxes (12L:12D), and the artificial 24-h light regimen (24L:0D) on the leukocyte populations and the T helper and regulatory type responses on rainbow trout (Oncorhynchus mykiss). Using flow cytometry analysis, we found that photoperiod induces changes in head kidney leukocyte subsets. The lymphoid subset increased in the 16L:8D summer solstice regime. The analysis using antibodies against B and T cells showed the increase of CD4-1(+) T lymphocytes and other unidentified lymphoid cells, with no changes in the B cells. To investigate the modulatory influence of the photoperiod on the fish T cell response, we quantified in the head kidney the transcript levels of genes involved in the Th1 type response (t-bet, ifn-gamma, il-12p35, il-12p40c), Th2 type response (gata3, il-4/13a), Th17 response (ror-gamma il-17a/f), T regulatory response (foxp3 alpha, il-10a, tgf-beta 1), and the T cell growth factor il-2. The results showed that the seasonal photoperiod alone has a limited influence on the expression of these genes, as the only difference was observed in il-14/13a and il-10a transcripts of fish kept on the 16L:8D regimen. In addition, the 24L:0D treatment used in aquaculture produces a reduction of il-14/ 13a and il-17a/f. We also evaluated the effect of photoperiod in the presence of an antigenic stimulus. Thus, in fish immunized with the recombinant viral protein 1 (rVP1) of infectious pancreatic necrosis virus (IPNV), the photoperiod had a striking influence on the type of adaptive immune response. Each photoperiod fosters a unique immune signature of antigenic response. A classical type 1 response is observed in fish subjected to the 16L:8D photoperiod. In contrast, fish in the 12L:12D photoperiod showed only the upregulation of il-12p40c. Further-more, none of the cytokines were increased in fish maintained on the artificial 24L:0D regimen, and a decrease in the master transcription factors (t-bet, ror-gamma t, and foxp3 alpha) was observed. Thus, fish on the 12L:12D and 24L:0D photoperiod appear hyporesponsive regarding the T cell response. Altogether, this study showed that photo-periods modify the magnitude and quality of the T-helper response in rainbow trout and thus impact essential mechanisms for the generation of immune memory and protection against microorganisms. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Andrographolide and Fucoidan Induce a Synergistic Antiviral Response In Vitro Against Infectious Pancreatic Necrosis Virus(MDPI, 2025-06-03) ;FRAZAO, MATEUS ;ESPINOZA, DANIELA ;CANALES-MUÑOZ, SERGIO ;MILLÁN-HIDALGO, CATALINAULLOA-SARMIENTO, BENJAMÍNAndrographolide, fucoidan, or a combination of both compounds were evaluated to determine their effects on the antiviral response in the Atlantic salmon macrophage-like cell line (SHK-1) infected with infectious pancreatic necrosis virus (IPNV). We assessed the transcript expression levels of key molecules involved in the interferon (IFN)-dependent antiviral response, as well as the viral load in cells treated with these compounds. In non-infected cells, incubation with either fucoidan, andrographolide, or a mixture of both resulted in an increase in the transcript expression of IFN alpha 1 and various interferon-stimulated genes (ISGs). In IPNV-infected cells, treatment with either fucoidan or andrographolide separately did not significantly enhance the antiviral response compared to that of infected cells that had not previously been treated with these compounds. In contrast, the combination of andrographolide and fucoidan led to a marked increase in the transcript expression of viperin and a significant reduction in viral load. Overall, combining andrographolide and fucoidan resulted in a greater reduction in IPNV viral load in infected cells than that noted when the compounds were administered individually. Our findings suggest that pre-incubation with this mixture promotes the establishment of a protective antiviral state against IPNV, likely mediated by an IFN-dependent response. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, The Comparative Analysis of Two RT-qPCR Kits for Detecting SARS-CoV-2 Reveals a Higher Risk of False-Negative Diagnosis in Samples with High Quantification Cycles for Viral and Internal Genes (Publication with Expression of Concern)(WILEY, 2022-07-05) ;LURASCHI, ROBERTO ;BARRERA-AVALOS, CARLOS; ;ALARCÓN, JAVIERAMELLA-TORRES, ANDREAThe early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the real-time quantitative polymerase chain reaction (RT-qPCR) as a gold-standard molecular tool has allowed to test and trace the viral spread and the isolation of COVID-19-infected patients. The detection capacity of viral and internal genes is an essential parameter to consider and analyze during the assay. In this study, we analyze the performance of the two commercial RT-qPCR kits used in Chile, TaqMan (TM) 2019-nCoV Control Kit v1 (Thermo Fisher) and MaxCov19 (TAAG Genetics), for the COVID-19 diagnosis from nasopharyngeal swab samples (NPSs). Our results show a lower sensitivity of the TAAG kit compared to the Thermo Fisher kit, even in the detection of SARS-CoV-2 mutations associated with its variants. This study reinforces the relevance of evaluating the performance of RT-qPCR kits before being used massively since those with lower sensitivity can generate false negatives and produce outbreaks of local infections. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Sensitivity analysis of rapid antigen tests for the Omicron SARS-CoV-2 variant detection from nasopharyngeal swab samples collected in Santiago of Chile(FRONTIERS MEDIA SA, 2022-10-20) ;BARRERA-AVALOS, CARLOS ;MENA, JAVIER ;LURASCHI, ROBERTO ;ROJAS, PATRICIOMATELUNA-FLORES, CARLOSThe COVID-19 pandemic continues to be a concern and keeps global health authorities on alert. The RT-PCR technique has been the gold-standard assay for detecting the SARS-CoV-2 virus. However, rapid antigen tests (RATs) have been widely used to increase the number of tests faster and more efficiently in the population. Nevertheless, the appearance of new viral variants, with genomic mutations associated with greater contagiousness and immune evasion, highlights the need to evaluate the sensitivity of these RATs. This report evaluates the sensitivity of SD Biosensor-Roche, Panbio (TM), and Clinitest (R) RATs widely used in Santiago de Chile in the detection of the Omicron variant from Nasopharyngeal samples (NPSs), the most predominant SARS-CoV-2 variant in Chile and the world. SD Biosensor-Roche shows a detection sensitivity of 95.7% in the viral amplification range of 20 <= Cq < 25, while Panbio (TM) and Clinitest (R) show 100% and 91.3%, respectively. In the viral amplification ranges of 25 <= Cq < 30, the detection sensitivity decreased to 28% for SD Biosensor-Roche, 32% for Panbio (TM), and 72% for Clinitest (R). This study indicates that the tested RATs have high sensitivity in detecting the Omicron variant of concern (VOC) at high viral loads. By contrast, its sensitivity decreases at low viral loads. Therefore, it is suggested to limit the use of RATs as an active search method, considering that infections in patients are increasingly associated with lower viral loads of SARS-CoV-2. These antecedents could prevent contagion outbreaks and reduce the underestimation of the current Omicron variant circulation at the local level. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, CXCL9-11 chemokines and CXCR3 receptor in teleost fish species(ELSEVIER, 2022-12) ;VALDÉS, NATALIA ;CORTÉS, MARCOS ;BARRAZA, FELIPE; IMARAI, MÓNICAThe coordinated migration of immune cells from lymphoid organs to in or out of the bloodstream, and towards the site of infection or tissue damage is fundamental for an efficient innate and adaptive immune response. Interestingly, an essential part of this movement is mediated by chemoattractant cytokines called chemokines. Although the nature and function of chemokines and their receptors are well documented in mammals, much research is needed to accomplish a similar level of understanding of the role of chemokines in fish immunity. The first chemokine gene identified in teleosts (rainbow trout, Oncorhynchus mykiss) was CK1 in 1998. Since then, the identification of fish chemokine orthologue genes and characterization of their role has been more complex than expected, primarily because of the whole genome duplication processes occurring in fish, and because chemokines evolve faster than other immune genes. Some of the most studied chemokines are CXCL9, CXCL10, CXCL11, and the CXCR3 receptor, all involved in T cell migration and in the induction of the T helper 1 (Th1) immune response. Data from the zebrafish and rainbow trout CXCL9-11/CXCR3 axis suggest that these chemokines and the receptor arose early in evolution and must be present in most teleost fish. However, the pieces of knowledge also indicate that different numbers of gene copies can be present in different species, with distinct regulatory expression mechanisms and probably, also with different roles, as the differential expression in fish tissues suggest. Here, we revised the current knowledge of the CXCL9-11/CXCR3 axis in teleost fishes, identifying the gaps in knowledge, and raising some hypotheses for the role of CXCL9, CXCL10 CXCL11, and CXCR3 receptor axis in fish, which can encourage further studies in the field. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Evaluation of the Immune Response Induced by CoronaVac 28-Day Schedule Vaccination in a Healthy Population Group(FRONTIERS MEDIA SA, 2022-01-31) ;ESCOBAR, ALEJANDRO; ;ACEVEDO, MÓNICA L. ;ALONSO-PALOMARES, LUISVALIENTE-ECHEVERRÍA, FERNANDOCoronaVac vaccine from Sinovac Life Science is currently being used in several countries. In Chile, the effectiveness of preventing hospitalization is higher than 80% with a vaccination schedule. However, to date, there are no data about immune response induction or specific memory. For this reason, we recruited 15 volunteers without previous suspected/diagnosed COVID-19 and with negative PCR over time to evaluate the immune response to CoronaVac 28 and 90 days after the second immunization (dpi). The CoronaVac administration induces total and neutralizing anti-spike antibodies in all vaccinated volunteers at 28 and 90 dpi. Furthermore, using ELISpot analysis to assay cellular immune responses against SARS-CoV-2 spike protein, we found an increase in IFN-gamma- and Granzyme B-producing cells in vaccinated volunteers at 28 and 90 dpi. Together, our results indicate that CoronaVac induces a robust humoral immune response and cellular immune memory of at least 90 dpi. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, The Rapid Antigen Detection Test for SARS-CoV-2 Underestimates the Identification of COVID-19 Positive Cases and Compromises the Diagnosis of the SARS-CoV-2 (K417N/T, E484K, and N501Y) Variants(FRONTIERS MEDIA SA, 2022-01-03) ;BARRERA-AVALOS, CARLOS ;LURASCHI, ROBERTO ;VALLEJOS-VIDAL, EVA ;MELLA-TORRES, ANDREAHERNÁNDEZ, FELIPETimely detection of severe acute respiratory syndrome due to coronavirus 2 (SARS-CoV-2) by reverse transcription quantitative polymerase chain reaction (RT-qPCR) has been the gold- strategy for identifying positive cases during the current pandemic. However, faster and less expensive methodologies are also applied for the massive diagnosis of COVID-19. In this way, the rapid antigen test (RAT) is widely used. However, it is necessary to evaluate its detection efficiency considering the current pandemic context with the circulation of new viral variants. In this study, we evaluated the sensitivity and specificity of RAT (SD BIOSENSOR, South Korea), widely used for testing and SARS-CoV-2 diagnosis in Santiago of Chile. The RAT showed a 90% (amplification range of 20 <= Cq <25) and 10% (amplification range of 25 <= Cq <30) of positive SARS-CoV-2 cases identified previously by RT-qPCR. Importantly, a 0% detection was obtained for samples within a Cq value>30. In SARS-CoV-2 variant detection, RAT had a 42.8% detection sensitivity in samples with RT-qPCR amplification range 20 <= Cq <25 containing the single nucleotide polymorphisms (SNP) K417N/T, N501Y and E484K, associated with beta or gamma SARS-CoV-2 variants. This study alerts for the special attention that must be paid for the use of RAT at a massive diagnosis level, especially in the current scenario of appearance of several new SARS-CoV-2 variants which could generate false negatives and the compromise of possible viral outbreaks. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Analysis by real-time PCR of five transport and conservation mediums of nasopharyngeal swab samples to COVID-19 diagnosis in Santiago of Chile(WILEY, 2022-03) ;BARRERA‐AVALOS, CARLOS ;LURASCHI, ROBERTO ;VALLEJOS‐VIDAL, EVA ;FIGUEROA, MAXIMILIANOARENILLAS, ESTEBANDue to the COVID-19 pandemic, many transport kits have been manufactured to preserve and transport nasopharyngeal swab samples (NPSs) from patients. However, there is no information on the performance of the different virus transport media (VTM) used in COVID-19 diagnosis in the population of Santiago de Chile. We compared the RT-qPCR amplification profile of five different viral transport kit mediums, including DNA/RNA Shield (TM), NAT, VTM-N, Ezmedlab (TM), and phosphate-buffered saline (PBS), for NPSs from Central Metropolitan Health Service, Santiago, Chile. The DNA/RNA Shield (TM) medium showed a better performance in terms of Cq and RFU values for the internal reference RNase P and viral ORF1ab probes. By contrast, the PBS transport medium registered higher Cq values for the viral and reference gene, compared to the other VTM. DNA/RNA Shield (TM) shows higher relative fluorescence units (RFUs) and lower Cq values for the reference gene. Collectively, our results suggest that the PBS medium could compromise the sample diagnosis because of its lower RT-qPCR performance. The NAT, Ezmedlab and VTM-N, and DNA/RNA Shield (TM) media show acceptable RT-qPCR parameters and, consequently, seem suitable for use in COVID-19 diagnosis.
