    Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study
    (MDPI, 2026-07-02)
    FUENTES-BARRÍA, HÉCTOR
    ;
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: We aimed to compare the agreement and reliability of the G-Force system (force plate and load cell) for the mid-thigh isometric pull test in physically active adults. Methods: Eighteen participants (age: 27.6 years; BMI: 27.8 kg/m(2)) performed three maximal IMTP trials under standardized conditions. Force-time data were collected simultaneously from both systems. Peak force and rate of force development (RFD) were analyzed. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Paired t-tests and Cohen's d evaluated systematic differences. Linear regression analyses were conducted to assess proportional bias. Results: Peak force showed excellent agreement (ICC = 0.999; 95% CI: 0.998-1.000) but with a positive fixed bias (84.48 N) and narrow limits of agreement (42.10 to 126.90 N), indicating consistently higher values from the force plate. A statistically significant difference was observed (p < 0.001; d = 3.90). Although the standardized effect size was large, the absolute bias between devices was relatively small (84.48 N; similar to 6% of mean peak force). The elevated d value reflects the low variability of the inter-system differences rather than a substantial absolute discrepancy. Accordingly, the results indicate a consistent systematic bias that may affect direct interchangeability of absolute values despite the excellent agreement observed between systems. No proportional bias was detected (p = 0.159). In contrast, RFD max showed lower agreement (ICC = 0.887; 95% CI: 0.699-0.958), with a negative bias (-1361 N/s) and wide limits of agreement (-6168 to 3445 N/s). Differences were significant (p = 0.031; d = 0.55), with no proportional bias (p = 0.268). Conclusions: The G-Force system demonstrates acceptable agreement for peak force but cannot be considered interchangeable with force plate measurements due to the presence of substantial systematic bias. In contrast, agreement for RFD is reduced, indicating greater sensitivity of early-phase force-time measures to methodological differences between systems.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Multivariate Neuromuscular Profile and Principal Component Analysis: A Pilot Study in Professional Female Soccer Players
    (MDPI, 2026-07-28)
    ROMERO-VERA, LUIS
    ;
    ULLOA-DÍAZ, DAVID
    ;
    CONCHA-POBLETE, JONATHAN
    ;
    SANDOVAL-CÁRCAMO, MISAEL
    ;
    CARVAJAL-PARODI, CLAUDIO
    Background: Professional women's football requires precise neuromuscular characterisation because of the high mechanical demands associated with acceleration, deceleration, jumping, braking, landing, and rapid force production. The aim was to characterise the multivariate neuromuscular profile derived from the countermovement jump (CMJ) and isometric mid-thigh pull (IMTP), and to examine neuromuscular components according to tactical positions in professional female football players. Methods: Twenty-three professional female football players were assessed using the CMJ and IMTP. Force-time, impulse, rate of force development, jump performance, landing, and inter-limb imbalance variables were extracted. Principal component analysis (PCA) was applied to the standardised variables, and individual component scores were compared according to tactical positions using one-way analysis of variance (ANOVA). Results: The first five principal components explained 79.19% of the total variance. PC1 represented the propulsive force and the rate of force development; PC2 reflected total force and mechanical impulse; PC3 represented early explosiveness; PC4 grouped indicators of inter-limb imbalance; and PC5 integrated jump performance and landing control. No statistically significant differences were observed between tactical positions. Conclusions: The combination of CMJ, IMTP, and PCA enabled multiple muscle-force variables to be synthesised into interpretable neuromuscular dimensions. The findings provide preliminary and exploratory evidence to support the individual monitoring of female football players. Given the low participant-to-variable ratio, the PCA findings should be considered exploratory.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study
    (MDPI, 2025-11-22) ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    AGUILERA-EGUÍA, RAÚL
    ;
    ROCO-VIDELA, ÁNGEL
    ;
    Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 +/- 4.97 years; body mass index: 25.79 +/- 3.02 kg/m(2)) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland-Altman analysis and Pearson's correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86-0.91) and moderate-to-good inter-platform reliability (ICC = 0.75-0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75-0.87) and higher variability (CV = 47-57%). Bland-Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R-2 = 0.55-0.77; beta = 0.74-0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Reliability and Repeatability of the Low-Cost G-Force Load Cell System in Isometric Hip Abduction and Adduction Tests: A Pilot Study
    (MDPI, 2025-10-27)
    GARRIDO-OSORIO, VÍCTOR
    ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    SANHUEZA-GONZÁLEZ, SEBASTIÁN
    ;
    SANDOVAL-JELVES, CATARÍ
    ;
    AGUILERA-EGUÍA, RAÚL
    Background/Objectives: Low-cost portable load cell dynamometers allow for real-time assessment of muscular strength. This study evaluated the reliability and repeatability of the G-Force load cell system during isometric hip abduction and adduction in young physically active Chilean adults. Methods: In total, 24 participants (19 men, 5 women) performed two maximal voluntary contractions per movement, repeated after a 24 h interval. Measured variables included Peak Force, peak rate of force development (Peak RFD), RFD at 50, 100, and 200 ms (RFD50, RFD100, RFD200), and maximum jerk. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV%) and Bland-Altman plots. Results: Peak Force showed excellent within-day (ICC = 0.94-0.96) and high between-day reliability (ICC = 0.87-0.89; CV = 20-30%). Bland-Altman analysis indicated negligible bias for Peak Force in abduction (-6.54 N; 95% CI -19.55 to 6.47) and adduction (-17.57 N; 95% CI -37.24 to 2.09), confirming the absence of systematic error. Peak RFD, RFD50-200, and maximum Jerk showed moderate repeatability and lower between-day reliability (ICCs = 0.39-0.70; CVs = 34-57%), indicating higher variability in explosive force indices compared with maximal strength. Conclusions: The G-Force load cell reliably measures maximal isometric hip strength, while Peak RFD, RFD50-200, and maximum jerk should be interpreted cautiously. These findings support the device as a practical, low-cost tool for sports and rehabilitation, though future studies should validate dynamic indices in larger and more diverse populations.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Relationship of Nutritional Status and Physical Activity Level with Dynamic Postural Balance in Young Adults
    (MDPI, 2025-04-17)
    GUZMÁN-MUÑOZ, EDUARDO
    ;
    ;
    MONTALVA-VALENZUELA, FELIPE
    ;
    ALARCÓN-RIVERA, MIGUEL
    ;
    VALDES-BADILLA, PABLO
    The increasing prevalence of excess body weight and physical inactivity among young adults raises concerns about their impact on dynamic postural control. This study aimed to examine the relationship of nutritional status and physical activity level (PAL) with dynamic postural balance in young adults. A cross-sectional study was conducted with 189 young adults (81 females and 108 males; aged 18-29 years). Nutritional status was determined using BMI, and PAL was assessed with the IPAQ-SF. Dynamic postural balance was measured using the Modified Star Excursion Balance Test (SEBTm) in three directions: anterior, posteromedial (PM), and posterolateral (PL). Regression analysis showed no significant associations in the anterior direction (adjusted model by sex R-2 = 0.051; p > 0.05). However, for the PM direction, the adjusted model (R-2 = 0.289) identified nutritional status (B = 2.784; p = 0.015), PAL (B = 2.962; p = 0.011), and sex (B = 8.248; p < 0.001) as significant predictors of postural balance performance. Similarly, in the PL direction, the adjusted model (R-2 = 0.275) confirmed significant associations for nutritional status (B = 2.413; p = 0.004), PAL (B = 4.203; p = 0.031), and sex (B = 7.712; p < 0.001). These findings suggest that both nutritional and behavioral factors contribute to dynamic balance performance in young adults, particularly in directions with greater postural demands.
  • Algunas métricas están ocultas. Revise sus 
    Tipo de ítem:Publicación,
    Carta al Director
    (ARAN EDICIONES, S L, 2023-01-01)
    AGUILERA-EGUÍA, RAÚL ALBERTO
    ;
    YÁÑEZ-BAEZA, CRISTIAN
    ;
    FUENTES-BARRÍA, HÉCTOR
    ;
    ;
    Universidad de Las Américas, Facultad de Salud y Ciencias Sociales, Chile
    Introduction: Cardiovascular diseases are the most important cause of death worldwide.The etiology is multifactorial, they may be influenced by various factors such as diet, lifestyle, level of exercise or genetics.The large number of genes involved, as well as its various forms, can influence the risk of cardiovascular diseases through different forms.Aim: To determine the relationship between different genetic polymorphisms and individual risk of CHD in child and adult population.Methods: A literature search was performed using PubMed database.The search was limited to a period of ten years and meta-analysis performed in humans.Results: The relationship between the risk of cardiovascular disease and the following genetic polymorphisms: chromosome 9p21, apolipoprotein A5, apolipoprotein E2, E3 and E4, gen PPARG or PPARϒ, genes involved in lipid metabolism, MTHFR gene, cytochrome P450, factor V, coagulation factor Leiden (FVL) and gen VKORC was reviewed.Conclusions: We have identified a number of genes related to cardiovascular disease.The genetic can influence directly or indirectly on cardiovascular risk by modifying risk factors for cardiovascular or acting on the medication used to treat it.