Ciencia Abierta UDLA
URI permanente para esta comunidadhttps://repositorio.udla.cl/handle/udla/2336
Producción científica, personas, proyectos, datos, propiedad industrial, tesis, unidades académicas y resultados de creación artística vinculados a UDLA.
Examinar
6 resultados
Resultados de la búsqueda
- Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Inter-Session Reliability of an Isometric Muscle Strength Protocol in Older Adults(MDPI, 2026-01-09) ;ANDRADES-RAMÍREZ, OSCAR ;CEBALLOS-SEPULVEDA, DOMINGO ;FUENTEALBA-MARTÍNEZ, BENJAMÍN ;VENEGAS-COFRÉ, BENJAMÍNVALENZUELA-ZIEBALLE, VÍCTORBackground: The objective of this study was to analyze the absolute and relative reliability intersession for a maximal isometric muscle strength protocol in the bilateral seated bench press (BSBP), bilateral seated row (BSR), unilateral seated knee right extension (USKER) and unilateral seated knee left extension (USKEL) in a population of older adults. Methods: Eighteen older adults (age = 69.38 +/- 5.06 years; weight = 75.79 +/- 14.18 kg; height = 1.61 +/- 0.08 m; BMI = 28.98 +/- 5.04 kg/m(2). The maximal isometric muscle strength assessment was performed in a seated position. Participants were asked to exert maximum effort during the exercise. The BSBP and BSR assessments were performed bilaterally with shoulders and elbows at 90 degrees, while the USKER and USKEL assessments were performed unilaterally. Three sets of 5 secondswere performed with a 3 minutes rest between measurements until maximum isometric strength was reached in all four measurements. Results: In the inter-session reliability measurements, acceptable absolute reliability was presented for BSR and USKER, and extremely high reliability for the BSBP and USKEL measures. In addition, extremely high relative reliability was reported for all assessments of maximum isometric muscle strength, with no significant differences were observed (p > 0.05) and an ES classified as null (ES < 0.12). Conclusions: The main results of this study show that maximal isometric muscle strength in bilateral seated bench press, bilateral seated row, and unilateral seated right and left knee extension, assessed using the Chronojump Force Sensor Kit, is reliable and reproducible for the elderly population. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effect of a muscle strength training program on the gait test and dynamic balance in older adults: a pilot study(UNIV MALAGA, 2026-06-30) ;ANDRADES-RAMÍREZ, OSCAR ;ALFARO CASTILLO, BRYAN; ;CASTILLO-QUEZADA, HUMBERTOSEGUEL-LÓPEZ, MARÍAOlder adults (OA) constitute a rapidly growing age group in the current population, posing a global challenge that impacts the economy and public health. The objective of this study was to analyze the effect of a muscle strength program at 60% of 1RM on the 6-minute walk test and the stand-up-and-walk test in OA. Eleven OA participants took part in an 8-week muscle strength program with three 45-minute sessions per week, consisting of three sets of 6-8 repetitions with 2 minutes and 30 seconds of rest between sets. The training program resulted in significant increases in strength assessments (p < 0.003-p < 0.005). Additionally, in the 6-minute walk test, an increase in distance covered and a significant decrease (p < 0.02) in timed-up-and-go test time were reported. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Bilateral strength balance of knee extensor and flexor muscles in female soccer players(FRONTIERS MEDIA SA, 2025-10-03) ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID; ;ALFARO-CASTILLO, BRYANMUÑOZ-BUSTOS, GUSTAVOBackground: The aim of our study was analyze the bilateral strength balance of the knee extensor and flexor muscles in female soccer players. Methodology: Participated in this study twenty-three professional female soccer players. The volunteer participants of the study were eligibly if: (a) signing of informed consent, (b) 5 years of sporting experience as a soccer player and have experience with training and evaluation of muscle strength in the lower limb, (c) participate in five weekly training sessions (d) no musculoskeletal pathology in the lower limbs 6 months prior to the evaluation date. The assessment was performed unilaterally, with peak muscle strength values recorded using the FEMD device software at a constant velocity of 0.4 m s(-1). The range of motion (ROM) was 90 degrees-0 degrees of joint extension in the sitting position and 150 degrees-90 degrees of flexion in the prone position. Each participant was required to perform their maximum effort for all repetitions. Results: Bilateral strength balance measurements were obtained in the range of 10.68%-13.80% for maximum muscle strength in knee extension and 13.27%-15.21%. No significant differences (p > 0.05) were found in the comparison of independent means for maximum muscle strength between the knee extension and flexion in the concentric and eccentric phases. Significant differences (p < 0.01) and small ES (ES < 3.32) were found in peak muscle strength measurements of the dominant and non-dominant lower extremity in the unilateral comparison of the extensor muscle and the flexor muscle group in the concentric and eccentric phase. Conclusion: In the analysis of bilateral strength balance, lower indices are presented in the knee extensor compared to the flexor, these bilateral indices would reveal intrinsic and extrinsic risk factors for musculoskeletal injuries in the hamstring muscles and anterior cruciate ligament of professional soccer players. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Effects of exercise, physical activity and sports on physical fitness and body composition in children and adolescents with Down syndrome: a systematic review(SPRINGERNATURE, 2025-07-01) ;MONTALVA-VALENZUELA, FELIPE ;ANDRADES-RAMÍREZ, OSCAR ;FERRARI, GERSON ;ADSUAR, JOSÉ CARMELOGORLA, JOSÉ IRINEUThe objective of this systematic review (PROSPERO: CRD42024503648) is to analyze and describe the effects of physical activity, exercise and sport interventions on fitness in children and adolescents with DS, to promote the improvement of physical fitness or in body composition. Following the PRISMA guidelines, a search strategy was carried out in four databases (Pubmed, WoS, Scopus and SciELO). Inclusion criteria: studies that used exercise, physical activity or sports as an intervention, which sought to improve physical fitness in children or adolescents with DS. PEDro scale and RoB-2 were used to evaluate the quality of the articles. Of the total number of participants, there were 342 participants in the experimental group and 279 in the control group. To synthesize the information from the studies, it was ordered based on authors and year of publication; country; study design; population; age of participants; intervention; instruments for data collection; results.16 investigations met the selection criteria. 8 studies mention an improvement in muscle fitness, 3 on cardiorespiratory fitness, 2 on body composition, 5 on balance, one on agility and one on functional capacity. The limitations of the study include the heterogeneity of the interventions, which makes their comparison and recommendation difficult, and the small number of articles of high methodological quality according to the scales used. It is concluded that physical activity, exercise or sports interventions with a duration of 30 min to 75 min with a frequency of two or three times a week, for a period of 6 weeks up to 36 weeks and even for at least 5 consecutive days, produce improvements in the components of fitness in children and adolescents with Down syndrome. Therefore, it is a viable strategy to seek improvements in the physical condition of children and adolescents with Down syndrome, which could lead to a general improvement in the life of this population. This review received no external funding. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Intra-session reliability of knee flexion-extension muscle strength monitored using a functional electromechanical dynamometer in female soccer players(FRONTIERS MEDIA SA, 2025-02-25) ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID ;CASTILLO, BRYAN ALFARO; MUÑOZ-BUSTOS, GUSTAVOBackground: The aim of the study was to analyze the relative and absolute reliability of intra-session comparisons of three repetitions in a protocol for assessment peak muscle strength in a knee extension and flexion exercise in competitive female soccer players. Methods: The participants in this research are professional level female soccer players. Peak muscle strength was assessed with functional electromechanical dynamometry (FEMD) for the knee muscles with the following movements: knee flexion (FLE) and extension (EXT). Each movement was assessed at a speed of 0.4 ms-1 unilaterally, recording peak muscle strength values in the concentric phase (CON) and an eccentric phase (ECC). Results: Null differences (ES < 0.19) were detected in the measurements of peak muscle strength of the extensors and flexors of the right and left knee in their concentric or eccentric phases. In the intra-set reliability measures, they reported acceptable absolute reliability (CV% < 9.71) and extremely high relative reliability (ICC = 0.92-0.98). Conclusion: In relation to the results of this study, it can be concluded that the FEMD presents a high relative and absolute intra-series reliability for the evaluation of muscle strength in knee extension and flexion in female soccer players. These reported antecedents may facilitate a more specific evaluation of the function of the muscles of the lower limbs. - Algunas métricas están ocultas. Revise suspreferencias de consentimiento
Tipo de ítem:Publicación, Intra-session reliability of isometric muscle strength of the bilateral standing press in female handball players(PEERJ INC, 2024-09-26); ;ANDRADES-RAMÍREZ, OSCAR ;ULLOA-DÍAZ, DAVID ;RODRÍGUEZ-PEREA, ÁNGELAHUERTA OJEDA, ÁLVAROBackground: Systematizing reliable protocols and procedures for strength assessment in handball has allowed for a more thorough kinetic analysis and increased precision in detecting training-induced changes in muscular strength. The evaluation of upper limb strength with a bilateral standing press (BSP) exercise in handball players approximates blocking actions in the defensive phase, pushing and fixation. Aim: The aim of this study was to analyze the relative and absolute reliability of intra-session comparisons in an isometric peak muscle strength protocol in a bilateral standing press (BSP) exercise among female handball players. Methods: Sixteen young female handball players at an international level, aged between 22 +/- 4 years, with no prior experience in using functional electromechanical dynamometers (FEMD) participated in this study. The participants initiated the assessment of maximum isometric force in a bipedal stance with a forward projection of the dominant foot between 20 and 30 cm. The knees were kept semi-flexed, and the hip extension of the non-dominant limb ranged from 15 to 20 degrees. Bilateral anterior push of the upper limb was performed with shoulder abduction and elbow flexion at 90 degrees, maintaining a pronated hand position. Participants were instructed to exert three sets of maximal force for 5 s in BSP exercise. Relative reliability was assessed using the model intraclass correlation (ICC) and absolute reliability was assessed using the coefficient of variation (CV) and standard error of measurement (SEM). For this study, the parameters of maximum and mean muscle strength were considered. Results: The results demonstrated high relative reliability (ICC 0.93-0.97) and absolute reliability (SEM 0.19-2.79) y (CV 4.78-9.03) for both mean force and peak force, with no significant differences between the sets (p > 0.05), indicating a negligible effect size (0.01-0.12). Conclusion: The mean and peak isometric muscle strength for the BSP exercise controlled with FEMD in female handball players exhibits high relative and absolute reliability between series.
