Mostrar el registro sencillo del ítem
Test–Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry
dc.contributor.author | Autor | Andrades Ramírez, Óscar Andrés | |
dc.contributor.author | Autor | Ulloa Díaz, David Leonardo | |
dc.contributor.author | Autor | Alfaro Castillo, Bryan Sebastián | |
dc.contributor.author | Autor | Arroyo Jofré, Patricio | |
dc.contributor.author | Autor | Castillo Paredes, Antonio Jonathan | |
dc.contributor.author | Autor | Chirosa Ríos, Luis Javier | |
dc.contributor.other | Carrera | Pedagogia en educacion Fisica | es |
dc.date.accessioned | Fecha ingreso | 2025-04-15T20:58:59Z | |
dc.date.available | Fecha disponible | 2025-04-15T20:58:59Z | |
dc.date.issued | Fecha publicación | 2024 | |
dc.identifier.citation | Referencia Bibliográfica | Sports, 12(7), 12 p. | es |
dc.identifier.issn | ISSN | 2075-4663 | |
dc.identifier.uri | URL | http://repositorio.udla.cl/xmlui/handle/udla/1724 | |
dc.description.abstract | Resumen | The purpose of the study was to analyze the test–retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test–retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65–5.02%; ICC = 0.99–0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71–9.61%; ICC = 0.98–0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963–0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD. | es |
dc.language.iso | Lenguaje ISO | en | es |
dc.publisher | Editor | MDPI | es |
dc.subject | Palabras Claves | Inamómetros (LC) | es |
dc.subject | Palabras Claves | Isokinetic | es |
dc.subject | Palabras Claves | Muscular strength | es |
dc.subject | Palabras Claves | Confiabilidad (LC) | es |
dc.title | Título | Test–Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry | es |
dc.type | Tipo de Documento | Artículo | es |
dc.identifier.doi | dc.identifier.doi | 10.3390/sports12070175 | |
dc.udla.privacidad | dc.udla.privacidad | Documento público | es |