Show simple item record

dc.contributor.authorAuthorHuerta Ojeda, Álvaro.
dc.contributor.authorAuthorRiquelme Guerra, Miguel.
dc.contributor.authorAuthorCoronado Román, Walter.
dc.contributor.authorAuthorYeomans, María-Mercedes
dc.contributor.authorAuthorFuentes-Kloss, Rodrigo.
dc.date.accessionedDate Accessioned2024-09-03T19:21:33Z
dc.date.availableDate Available2024-09-03T19:21:33Z
dc.date.issuedDate Issued2022
dc.identifier.citationReferencia BibliográficaInternational Journal of Performance Analysis in Sport, 22(3), 16 p.
dc.identifier.issnISSN1474-8185
dc.identifier.uriURIhttp://repositorio.udla.cl/xmlui/handle/udla/1650
dc.identifier.uriURIhttps://www.tandfonline.com/toc/rpan20/current
dc.description.abstractAbstractMaximal oxygen consumption (VO2max) and maximal power output (Pmax) play a preponderant role in the performance of rowers. This study aims to describe and analyse the kinetics of ventilatory and mechanical parameters in novice male rowers on the rowing ergometer. Twelve male novice rowers were part of the study–descriptive with a selective non-probabilistic cross-sectional design. The variables were VO2max and Pmax. The kinetics of the variables were observed in an Incremental Test (IT) and a 2,000 m time trial (2,000mTT). The differences between the tests were established by Student’s t-test (p < 0.05). In both protocols, the VO2max reached 330–345 s. Between IT and the 2,000mTT there were significant differences in the VO2max (52.7 ± 3.3 vs 55.9 ± 3.4 mLO2·kg−1·min−1, p ˂ 0.01) and Pmax (334.7 ± 20.2 vs 269.5 ± 31.3 W, p ˂ 0.001). The novice rowers’ low physiological capacity and efficiency generated instability in the power output kinetics. A very large delta was observed between the maximum and minimum power output. Exploring tests with a shorter duration for novice rowers (360 s) and improving power output control in the different tests are suggested.
dc.format.extentdc.format.extent16 páginas
dc.format.extentdc.format.extent1.691Mb
dc.format.mimetypedc.format.mimetypePDF
dc.language.isoLanguage ISOeng
dc.publisherPublisherRoutledge
dc.sourceSourcesInternational Journal of Performance Analysis in Sport
dc.subjectSubject2,000 m time trial
dc.subjectSubjectMaximal oxygen uptake
dc.subjectSubjectNovice rowers
dc.subject.lcshdc.subject.lcshRemo (Deportes)
dc.titleTitleKinetics of ventilatory and mechanical parameters of novice male rowers on the rowing ergometer
dc.typeDocument TypeArtículo
dc.udla.catalogadordc.udla.catalogadorCBM
dc.udla.indexdc.udla.indexWoS
dc.udla.indexdc.udla.indexScience Citation Index Expanded
dc.udla.indexdc.udla.indexScopus
dc.udla.indexdc.udla.indexSPORTDiscus with Full Text
dc.identifier.doidc.identifier.doi10.1080/24748668.2022.2075670
dc.facultaddc.facultadFacultad de Salud y Ciencias Sociales


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record