Mostrar el registro sencillo del ítem

dc.contributor.authorAutorDivyah, Nagarajan
dc.contributor.authorAutorPrakash, Ramaiah
dc.contributor.authorAutorSrividhya, Sundaresan
dc.contributor.authorAutorAvudaiappan, Siva
dc.contributor.authorAutorGuindos, Pablo
dc.contributor.authorAutorMaureira Carsalade, Nelson
dc.contributor.authorAutorPrakash Arunachalam, Krishna
dc.contributor.authorAutorNoroozinejad Farsangi, Ehsan
dc.contributor.authorAutorRoco-Videla, Ángel
dc.date.accessionedFecha ingreso2024-09-03T19:20:34Z
dc.date.availableFecha disponible2024-09-03T19:20:34Z
dc.date.issuedFecha publicación2023
dc.identifier.citationReferencia BibliográficaBuildings, 13(6), 16 p.
dc.identifier.issnISSN2075-5309
dc.identifier.uriURLhttp://repositorio.udla.cl/xmlui/handle/udla/1516
dc.identifier.uriURLhttps://www.mdpi.com/journal/buildings
dc.description.abstractResumenThe steel-concrete composite column comprises a steel core and surrounding concrete. The purpose of the system is to provide analysis and design techniques for a newly invented class of laced steel-concrete composite short columns for cyclic axial loads. To minimize the increasing density issues associated with nominal strength concrete and in consideration of the depletion of natural resources required to produce concrete, factory-obtained lightweight sintered fly ash aggregates with and without basalt fiber are employed. The normal-weight concrete containing basalt fiber is shown to be more ductile than any other column. The axial deformation of columns LNA and LSA at failure was found to be 3.5 mm, whereas columns LNAF and LSAF reached an axial shortening of 4.5 mm at failure. The column LSAF was found to have 5.3% more energy absorption than the LSA and 11.5% less than the column LNAF. It was observed that the rigidity of these fabricated components had been enhanced. It was found that the section configuration with a lacing system had improved confinement effects and ductility. Comparing the finite element analysis to the experimental data revealed a strong connection with numerical modeling, with a variance of around 8.77%.
dc.format.extentdc.format.extent16 páginas
dc.format.extentdc.format.extent5.298Mb
dc.format.mimetypedc.format.mimetypePDF
dc.language.isoLenguaje ISOeng
dc.publisherEditorMDPI
dc.rightsDerechosCreative Commons Attribution License (CC BY)
dc.sourceFuentesBuildings
dc.subjectPalabras ClavesLaced built-up column
dc.subjectPalabras ClavesBasalt fiber
dc.subjectPalabras ClavesStrain behavior
dc.subjectPalabras ClavesFinite element
dc.subjectPalabras ClavesDeformation
dc.subject.lcshdc.subject.lcshHormigón liviano
dc.titleTítuloExperimental and numerical investigations of laced built-up lightweight concrete encased columns subjected to cyclic axial load
dc.typeTipo de DocumentoArtículo
dc.udla.catalogadordc.udla.catalogadorCBM
dc.udla.indexdc.udla.indexWoS
dc.udla.indexdc.udla.indexScience Citation Index Expanded
dc.udla.indexdc.udla.indexScopus
dc.udla.indexdc.udla.indexNatural Science Collection
dc.udla.indexdc.udla.indexDOAJ
dc.udla.indexdc.udla.indexINSPEC
dc.udla.indexdc.udla.indexMaterials Science & Engineering Collection
dc.identifier.doidc.identifier.doi10.3390/buildings13061444
dc.facultaddc.facultadFacultad de Salud y Ciencias Sociales


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem